Omron ZW Series User Manual page 169

Displacement sensor, confocal fiber type
Hide thumbs Also See for ZW Series:
Table of Contents

Advertisement

■ LED OFF
LED OFF input
LED
ENABLE output
Measurement
Item
T9
Measurement start response time
T10
Time of receiving LED OFF input
T11
Response time of LED OFF
T12
ENABLE response time after LEDs
are turned OFF
● Explanation of operations
(1)
The LED OFF signal is turned ON.
(2)
After the LED OFF signal is turned ON, the LEDs are turned OFF.
(3)
After the LEDs are turned OFF, the ENABLE signal is turned OFF.
(4)
The LED OFF signal is turned OFF.
(5)
After the LED OFF signal is turned OFF, the LEDs are turned ON.
(6)
After the LEDs are lit up, measurement is restarted and the ENABLE signal is
turned ON.
(1)
(2)
(3)
T10
T11
T12
ON
OFF
Turn ON
Turn OFF
ON
OFF
Measurement
3uT0
100 Ps
-
-
(4)
(5)
(6)
T11
T9
Turn ON
Clamp
Measurement
Minimum
Depends on the set
conditions
-
100 Ps
2uT0
Chapter 4
Timing Charts
Maximum
ZW
4-41
User's Manual

Advertisement

Table of Contents
loading

This manual is also suitable for:

Zw-s20Zw-s40

Table of Contents