Omron ZW Series User Manual page 162

Displacement sensor, confocal fiber type
Hide thumbs Also See for ZW Series:
Table of Contents

Advertisement

Chapter 4
Timing Charts
■ Peak/Bottom/Peak to peak/Average hold
Trigger output
(TIMING)
Reset output
(RESET)
Busy output
Judgment output
(HIGH/PASS/LOW)
Binary output
GATE output
Analog output
T3
Response time of analog output
T4
GATE signal rise time
T5
Output time of GATE signal
T6
Trigger input/reset input minimum
time'
T7
Response time of input
● Explanation of operations
(1)
The trigger signal is turned ON.
(2)
During the trigger input minimum time, when the trigger is input is ON, sampling
is started and the BUSY signal is turned ON.
(3)
After the end of measurement, the judgment results and binary data are output.
(4)
After the trigger signal goes OFF, sampling is ended and the judgment results
and binary data are output. The BUSY signal is also turned OFF.
(5)
After the judgment result and binary data output, the analog output is updated.
(6)
After the judgment result and binary data output, the GATE signal is turned ON.
(7)
The GATE output time after the GATE signal is turned ON, the GATE signal is
turned OFF.
(8)
The reset signal is turned ON. During the reset input minimum time, if the reset
signal is turned ON, the measured value is reset.
(9)
The judgment results and binary data are reset.
(10) After the judgment results and binary data are reset, the analog output is reset.
(11) After the judgment results and binary data are reset, the GATE signal is turned
ON.
(12) The GATE output time after the GATE signal is turned ON, the GATE signal is
turned OFF.
(13) The reset signal is turned OFF.
ZW
4-34
User's Manual
(1)
(2)
(3)
T7
T6
T7
ON
OFF
ON
OFF
ON
OFF
ON
OFF
Item
(4) (5)
(6)
(7)
(8)
T4
T5
T3
T7
Minimum
-
-
Setting value
(0.1 to 100.0 ms)
3 ms+T0
2 ms+T0
(12) (13)
(9)(10)
(11)
T6
T4
T5
T3
Maximum
0.1 ms
0.2 ms
Setting value
(0.1 to 100.0 ms)
-
3 ms+T0u2

Advertisement

Table of Contents
loading

This manual is also suitable for:

Zw-s20Zw-s40

Table of Contents