Chapter 3
Setting the Output Conditions
■ Setting the average value filter
The average of the measured values obtained based on the preset number of samples
can be output. Select this setting when you want to ignore sudden changes in
measured values.
1/2/4/8/16/32/64/128/256/512/
1024/2048/4096
(Default value: 256)
As an example, here is an explanation of the procedure for selecting the "128" average
count setting.
Operating procedure
Steps
1 - 4
For moving to FILTER, see steps 1 to 4 in p.3-15
5
6
7
ZW
3-16
User's Manual
Setting
Sets the average count.
Key operation
Display
ZERORST/ ESC
ESC
ZERORST/
ZERO/
ZERO/ SET
SET
ZERORST/
ZERORST/ ESC
ESC
ZERO/ SET
ZERO/
SET
RUN
RUN
H
L
FUN
FUN
L
TEACH
TEACH
Description
Select "Average filter" as the filter type.
Press
or
keys to select either of "AVE" and
press
key.
ZERO/ SET
ZERO/
SET
Select "128" as the average count.
The current setting value is displayed on the sub-
display.
Press
/
keys to enter the editing mode, and the
sub-display blinks.
Select "128" and press
RUN
RUN
Press
key for two seconds to enter the RUN
LIT
FUN
FUN
L
TEACH
TEACH
mode.
RUN
RUN
Description
key.
ZERO/ SET
SET
ZERO/