Connecting Fiber Cable
Connect the fiber cable on the Sensor Head to the Sensor Head connector on the
Controller as follows:
1.
Remove the protective caps from the controller's fiber connector and the
fiber cable.
Protective cap
Do not discard but keep the protective cap handy.
2.
Mate the convex section on the fiber cable with the groove on the fiber
connector and turn the threaded section clockwise while pushing in (see
figure 1).
(Figure 1)
Fiber cable
Fiber
connector
In the "No good" status in figure 2 and figure 3, optic signals cannot be transmitted
and correct measurement is not possible. Always check that the system is in the
"Good" status.
Protective cap
Fiber connector
Groove
Convex
section
Threaded
section
About Installation and Connection
Fiber cable
(Figure 2)
Good
(Figure 3)
Good
Chapter 1
No good
No good
ZW
1-15
User's Manual