Omron ZW Series User Manual page 172

Displacement sensor, confocal fiber type
Hide thumbs Also See for ZW Series:
Table of Contents

Advertisement

Chapter 4
Timing Charts
■ Binary output
● When the judgment results for all tasks are output at the same time (judgment value
mode (When the output target is a judgment value)
The binary output results can be acquired when the GATE output is ON.
Judgment output
(HIGH/PASS/LOW)
Binary output
GATE output
T0
Measurement cycle
T4
GATE signal rise time
T5
Output time of GATE signal
T15
Binary output update cycle
• Explanation of operations
(1)
The TASK2, 3 and 4 judgment results (HIGH/PASS/LOW) are output.
(2)
After the judgment result output, the GATE signal is turned ON.
(3)
The GATE output time after the GATE signal is turned ON, the GATE signal is
turned OFF.
(4)
After the binary output update cycle, the TASK2, 3 and 4 judgment results are
updated.
ZW
4-44
User's Manual
(1) (2)
T15
T4
T0
T5
Judge result
Judge result
ON
OFF
Item
(3)
(4)
Judge result
Judge result
Judge result
Minimum
0.5 ms
-
Setting value
(0.1 to 100.0 ms)
T0uUpdate cycle
Judge result
Judge result
Maximum
Depends on the set
conditions
0.2 ms
Setting value
(0.1 to 100.0 ms)
T0uUpdate cycle