Chapter 3
Setting the Output Conditions
As an example, here is an explanation of the procedure for selecting the "Lopass filter"
setting for the frequency filter type, and the "1 Hz" cut-off frequency filter setting.
Operating procedure
Steps
1 - 4
For moving to FILTER, see steps 1 to 4 in p.3-15
5
6
7
8
ZW
3-20
User's Manual
Key operation
Display
ZERORST/ ESC
ZERORST/
ESC
ZERO/ SET
SET
ZERO/
ZERORST/ ESC
ZERORST/
ESC
ZERO/
ZERO/ SET
SET
ZERORST/ ESC
ZERORST/
ESC
ZERO/ SET
SET
ZERO/
RUN
RUN
H
L
FUN
FUN
L
TEACH
TEACH
Select "Frequency filter" as the filter type.
Press
or
keys to select either of "FREQ" and
press
key.
ZERO/ SET
ZERO/
SET
Select "Lowpass filter" as the frequency filter type.
The current setting value is displayed on the sub-
display.
Press
/
keys to enter the editing mode, and the
sub-display blinks.
Select "LO.PASS" and press
Set "1" as the cut-off frequency.
"CUTOFF" is displayed on the main display and the
current setting value is displayed on the sub-display.
Press
key to enter the editing mode, and the
ZERO/ SET
ZERO/
SET
sub-display blinks.
To edit numerical values use
Enter "1" and press
RUN
RUN
Press
key for two seconds to enter the RUN
LIT
FUN
FUN
L
TEACH
TEACH
mode.
RUN
RUN
Description
key.
ZERO/ SET
ZERO/
SET
/
/
/
keys.
key.
ZERO/ SET
ZERO/
SET