Calibrating Sensor Head

Calibrate the Sensor Head by obtaining the dark data in the no-incoming light status.
• When using the sensor for the first time.
• When removing and inserting a fiber cable from/to the Controller.
• When extending a fiber cable.
The Sensor Head should be calibrated without any workpiece within the measuring range
or with the tip of the Sensor Head shielded from light with an object with diffuse reflection.
(Correct calibration is not possible with a transparent object, semi-transparent object, or
mirror. )
Without any workpiece
within the measuring range
Sensor head
Measuring range
Operating procedure
Steps
Key operation
1
RUN
RUN
FUN
FUN
L
TEACH
TEACH
2
ZERORST/ ESC
ZERORST/
3
ZERO/ SET
ZERO/
4
ZERORST/ ESC
ZERORST/
ZERO/ SET
ZERO/
With light shielded
Display
UNLIT
H
L
RUN
RUN
ESC
SET
ESC
SET
About Installation and Connection
Sensor head
Install an object with diffuse
reflection (metal, paper, plastic, etc.)
than the measurement range.
Measuring range
Description
RUN
RUN
Press
key for two seconds to enter the FUN
FUN
FUN
L
TEACH
TEACH
mode.
(For details on the functions of the
p.2-3.)
Press
or
keys to select either of "SYSTEM"
and press
key.
ZERO/ SET
ZERO/
SET
Press
or
keys to select either of "H.CALIB"
and press
key.
ZERO/
ZERO/ SET
SET
"OK/CAN" appears on the sub-display.
To execute press
key, or the
ZERO/ SET
ZERO/
SET
cancel.