Connecting Using Ethernet Cable
Connection Method
1.
Insert one end of the Ethernet cable
into the Ethernet connector of the
controller.
2.
Insert another end of the Ethernet
cable into the Ethernet connector of
the external device.
(Note)
Prepare commercially available Ethernet cable satisfying the following requirements:
-Category 5e or more, 30 m or less
-RJ45 connector (8-pin modular jack)
-For direct connection: Select cross cable.
-For connection through a network hub: Select straight cable.
Communication Settings
Set the Ethernet communication of the controller.
Set the IP address and subnet mask.
Set a three-digit value for each setting as shown below.
Setting [Display]
IP address [IPADDR]
Subnet mask [SUBNET]
IP1.IP2.IP3.IP4
IP1 : 1 to 223 (default value: 192)
IP2 : 0 to 255 (default value: 168)
IP3 : 0 to 255 (default value: 250)
IP4 : 1 to 254 (default value: 50)
SUB1.SUB2.SUB3.SUB4
SUB1 : 0 to 255 (default value: 255)
SUB2 : 0 to 255 (default value: 255)
SUB3 : 0 to 255 (default value: 255)
SUB4 : 0 to 255 (default value: 0)
Connecting Using Ethernet Cable
Ethernet connector
Ethernet cable
(Note)
Description
Chapter 5
ZW
5-5
User's Manual