Chapter 4
Timing Charts
■ Bank switching
BANK_SEL input
(BANK_SEL1/2/3)
BANK_OUT output
(BANK_OUT1/2/3)
ENABLE output
T7
Response time of input
T8
Bank switching time
T9
Measurement start response time
● Explanation of operations
(1)
The BANK_SEL signal is switched to the bank number switched to.
(2)
After the input response time, the measurement stops and the BUSY signal is
turned ON, then the bank switching operation is started.
(3)
After the bank switching ends, the BUSY signal is turned OFF and the
BANK_OUT signal is switched.
(4)
After the bank switching ends, the BUSY signal is turned OFF and the
BANK_OUT signal is switched.
ZW
4-40
User's Manual
BUSY output
Measurement
Measurement
Item
(3)
(1)
(2)
T7
T8
Clamp
Minimum
-
-
3uT0
(4)
T9
Measurement
Maximum
200 ms
100 ms
Depends on the set
conditions