Steps
Key operation
6
RUN
RUN
FUN
FUN
L
TEACH
TEACH
■ Operation settings at judgment output
Sets the hysteresis width for the upper and lower limits of judgments and the judgment
output timing.
Setting Threshold Value p.2-17
Setting [Display]
Hys [HYS]
Display
LIT
H
L
RUN
RUN
Set the hysteresis value for
the upper and lower limits of
judgments if the HIGH,
PASS, or LOW judgment is
unstable near the threshold
values.
Hysteresis width setting
range:
Range: 0 to 99.9999
(default value: 0.05 % of
Sensor Head measuring
range)
Example:
For the ZW-S40, 12 mm x
0.05% = 0.006 mm, as the
range is r6 mm.
Description
RUN
RUN
Press
key for two seconds to enter the RUN
FUN
FUN
L
TEACH
TEACH
mode.
Description
HIGH threshold
value
Measured value
LOW threshold
value
ON
HIGH output
OFF
ON
PASS output
OFF
ON
LOW output
OFF
Chapter 4
Settings for I/O
Hysteresis
(hysteresis width)
Action point
Return point
ZW
4-19