Panasonic FP-M Hardware Manual page 153

Table of Contents

Advertisement

Analog output data conversion characteristics
• The ranges of digital values to specify analog output are shown below:
- When analog I/O board is installed
K0 to K255 (0 to 5 V, 0 to 10 V, and 0 to 20 mA)
The range of digital values for specifying analog output
(8 bits resolution of special data registers DT9096 to DT9103)
<Analog I/O Board>
• 0 to 5 V range
255
Digital
200
data
(K)
100
0
1.96
Analog output (V)
• 0 to 20 mA range
255
Digital
200
data
(K)
100
0
- When D/A converter board is installed
K0 to K999 (0 to 5 V, 0 to 10 V, and 0 to 20 mA)
The range of digital values for specifying analog output
(10 bits resolution of special data registers DT9096 to DT9103)
<D/A Converter Board>
• 0 to 5 V range
1,000
Digital
500
data
(K)
0
2.5
Analog output (V)
• 0 to 20 mA range
1,000
Digital
500
data
(K)
0
7-4. Programming for Analog I/O, A/D Converter, and D/A Converter Boards
• 0 to 10 V range
255
Digital
200
data
(K)
100
0
3.92
5.0
7.84
15.7
Analog output (mA)
• 0 to 10 V range
1,000
Digital
500
data
(K)
0
5.0
10.0
Analog output (mA)
3.92
Analog output (V)
20
5.0
Analog output (V)
20.0
7.84
10
10.0
145