Display Network Monitor

Description
Use parameter 'Display Network Monitor' (9950) to view the values of network registers. This
is useful for troubleshooting. As data is transmitted, and the values of the registers change,
the display automatically updates to reflect the changes.
Note
The direction of data transmission shown on the screen is displayed as seen by the drive,
meaning that:
Figure C-1
1
2
3
4
5
6
NXGpro Communication
Function Manual, AB, A5E33486415A
Rx refers to data received into the drive
Tx refers to data transmitted from the drive.
Display Network Monitor Function
Format of the register value dis‐
play
Network for this register
Data direction
Global or non-global register
Register number
Register value
D = decimal format
H = hexadecimal format
The drive may be connected to 2 separate networks:
● NET 1
● NET 2
Rx = Data to Drive register
Tx = Data from Drive register
G = global register
N = non-global register
2-digit numeric field that indicates the number of the
register being shown.
● Tx 01-64 = Data from Drive 01 (ID 9401) to Data
from Drive 64 (ID 9464)
● Rx 01-64 = Data to Drive 01 (ID 9601) to Data to
Drive 64 (ID 9664)
The value of the register. Since the registers all con‐
tain 16-bit digital words, they range in value from
0-65535 (decimal), or 0-FFFF (hexadecimal).
C
299