48 ESP program features

Current pulse-start

Current pulse-start function enables when regular starting routines are not enough to
accelerate the motor. The most common reason can be pump waxing or
sedimentation. The function produces a series of thrusts to the pump impeller by
sending short high-current impulses.
You can adjust speed, magnitude and frequency of thrusts applied. After the Current
pulse-start routine is competed, the control is given to Kick-start function (if enabled)
and then proceed to production speed with additional help of the acceleration
assistance (if enabled).
Speed reference
75.61 Current pulse
speed reference
75.15 Starting speed
0
75.62 Current pulse
start current ref
Regular current
0
Settings
Parameter group
75 ESP reference setup
Pulse-start cycle 1
75.69 Current pulse
75.69 Current pulse
cycle time
cycle time
(page 421).
Last cycle
Pulse-start cycle 2
Time
Time