Summary of parameter groups

Group
01 Actual values
03 Input references
04 Warnings and faults
05 Diagnostics
06 Control and status words
07 System info
09 ESP signals
10 Standard DI, RO
11 Standard DIO, FI, FO
12 Standard AI
13 Standard AO
14 I/O extension module 1
15 I/O extension module 2
16 I/O extension module 3
19 Operation mode
20 Start/stop/direction
21 Start/stop mode
22 Speed reference selection
23 Speed reference ramp
40 Process PID set 1
41 Process PID set 2
Contents
Basic signals for monitoring the drive.
Values of references received from various sources.
Information on warnings and faults that occurred last.
Various run-time-type counters and measurements related to drive
maintenance.
Drive control and status words.
Information on drive hardware, firmware and application program.
ESP signals to monitor the pump.
Configuration of digital inputs and relay outputs.
Configuration of digital input/outputs and frequency inputs/outputs.
Configuration of standard analog inputs.
Configuration of standard analog outputs.
Configuration of I/O extension module 1.
Configuration of I/O extension module 2.
Configuration of I/O extension module 3.
Selection of local and external control location sources and
operating modes.
Start/stop/direction and run/start/jog enable signal source
selection; positive/negative reference enable signal source
selection.
Start and stop modes; emergency stop mode and signal source
selection; DC magnetization settings; autophasing mode
selection.
Speed reference selection; motor potentiometer settings.
Speed reference ramp settings (programming of the acceleration
and deceleration rates for the drive).
Speed error calculation; speed error window control configuration;
speed error step.
Speed controller settings.
Settings for the torque reference chain.
Settings for the frequency reference chain.
Drive operation limits.
Configuration of external events; selection of behavior of the drive
upon fault situations.
Configuration of signal supervision functions 1...3.
Configuration of maintenance timers/counters.
Motor thermal protection settings such as temperature
measurement configuration, load curve definition and motor fan
control configuration.
Peak value and amplitude logger settings.
Settings for user load curve.
Parameter values for process PID control.
A second set of parameter values for process PID control.
Parameters 149
Page
152
156
157
164
165
180
183
184
191
196
200
204
223
227
231
233
242
249
257
263
268
279
285
294
302
312
315
323
334
338
341
353