ABB +N5600 Firmware Instructions page 335

Single drive
Table of Contents

Advertisement

No.
Name/Value
Output frequency
Motor current
Motor torque
DC voltage
Power inu out
Speed ref ramp in
Speed ref ramped
Speed ref used
Torq ref used
Freq ref used
Process PID out
Process PID fbk
Process PID act
Process PID dev
Other
36.02
PVL filter time
0.00 ... 120.00 s
36.06
AL2 signal source
Zero
Motor speed used
Output frequency
Motor current
Motor torque
DC voltage
Power inu out
Speed ref ramp in
Speed ref ramped
Speed ref used
Torq ref used
Freq ref used
Process PID out
Process PID fbk
Process PID act
Process PID dev
Description
01.06 Output frequency
01.07 Motor current
(page 152).
01.10 Motor torque
(page 152).
01.11 DC voltage
(page 152).
01.14 Output power
(page 153).
23.01 Speed ref ramp input
23.02 Speed ref ramp output
24.01 Used speed reference
26.02 Torque reference used
28.02 Frequency ref ramp output
40.01 Process PID output actual
40.02 Process PID feedback actual
40.03 Process PID setpoint actual
40.04 Process PID deviation actual
Source selection (see
Terms and abbreviations
Defines a filtering time for the peak value logger. See
parameter
36.01 PVL signal
Peak value logger filtering time.
Selects the signal to be monitored by amplitude logger 2. The
signal is sampled at 200 ms intervals, and can be scaled
using parameter
36.07 AL2 signal
The results are displayed by parameters 36.40...36.49. Each
parameter represents an amplitude range, and shows what
portion of the samples fall within that range.
Amplitude logger 2 can be reset using parameter
loggers. The logger is also reset whenever the signal source
or scaling is changed. The date and time of the last reset are
stored into parameters
36.50
None (amplitude logger 2 disabled).
01.01 Motor speed used
01.06 Output frequency
01.07 Motor current
(page 152).
01.10 Motor torque
(page 152).
01.11 DC voltage
(page 152).
01.14 Output power
(page 153).
23.01 Speed ref ramp input
23.02 Speed ref ramp output
24.01 Used speed reference
26.02 Torque reference used
28.02 Frequency ref ramp output
40.01 Process PID output actual
40.02 Process PID feedback actual
40.03 Process PID setpoint actual
40.04 Process PID deviation actual
(page 152).
(page 257).
(page 257).
(page 263).
(page 279).
(page 285).
(page 341).
(page 341).
(page 341).
(page 341).
on page 148). -
source.
scaling.
and
36.51
respectively.
(page 152).
(page 152).
(page 257).
(page 257).
(page 263).
(page 279).
(page 285).
(page 341).
(page 341).
(page 341).
(page 341).
Parameters 335
Def/FbEq16
3
4
6
7
8
10
11
12
13
14
16
17
18
19
2.00 s
100 = 1 s
Ambient
temperature
36.09 Reset
0
1
3
4
6
7
8
10
11
12
13
14
16
17
18
19

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents