No.
Name/Value
10.99
RO/DIO control
word
Bit
Name
0
RO1
1
RO2
2
RO3
3...7
Reserved
8
DIO1
9
DIO2
10...15 Reserved
0000h...FFFFh
11

11 Standard DIO, FI, FO

11.01
DIO status
0000b...0011b
11.02
DIO delayed status
0000b...0011b
11.05
DIO1 function
Output
Input
Frequency
11.06
DIO1 output source
Not energized
Energized
Ready run
Enabled
Started
Magnetized
Running
Description
Storage parameter for controlling the relay outputs and digital
input/outputs eg. through the embedded fieldbus interface.
To control the relay outputs (RO) and the digital input/outputs
(DIO) of the drive, send a control word with the bit
assignments shown below as Modbus I/O data. Set the target
selection parameter of that particular data (58.101...58.124)
to
RO/DIO control
word. In the source selection parameter of
the desired output, select the appropriate bit of this word.
Description
Source bits for relay outputs RO1...RO3 (see parameters 10.24,
10.30).
Source bits for digital input/outputs DIO1...DIO3 (see parameters
and 11.10).
RO/DIO control word.
Configuration of digital input/outputs and frequency
inputs/outputs.
Displays the status of digital input/outputs DIO2 and DIO1.
The activation/deactivation delays (if any are specified) are
ignored. A filtering time (for input mode) can be defined by
parameter
10.51 DI filter
Example: 0010 = DIO2 is on, DIO1 is off.
This parameter is read-only.
Status of digital input/outputs.
Displays the delayed status of digital input/outputs DIO2 and
DIO1. This word is updated only after activation/deactivation
delays (if any are specified).
Example: 0010 = DIO2 is on, DIO1 is off.
This parameter is read-only.
Delayed status of digital input/outputs.
Selects whether DIO1 is used as a digital output or input, or a
frequency input.
DIO1 is used as a digital output.
DIO1 is used as a digital input.
DIO1 is used as a frequency input.
Selects a drive signal to be connected to digital input/output
DIO1 when parameter
11.05 DIO1 function
Output is off.
Output is on.
Bit 1 of
06.11 Main status word
Bit 0 of
06.16 Drive status word 1
Bit 5 of
06.16 Drive status word 1
Bit 1 of
06.17 Drive status word 2
Bit 6 of
06.16 Drive status word 1
time.
is set to Output.
(see page 166).
(see page 167).
(see page 167).
(see page 168).
(see page 167).
Parameters 191
Def/FbEq16
0000h
10.27
and
11.06
1 = 1
-
1 = 1
-
1 = 1
Output
0
1
2
Ready run
0
1
2
4
5
6
7

Hide quick links: