A-1-3 Rating And Characteristics Of Options; A-1-4 Waterproof Packing - Omron E5*D series User Manual

Digital temperature controllers
Hide thumbs Also See for E5*D series:
Table of Contents

Advertisement

Sampling cycle
Insulation resistance
Dielectric strength
Malfunction vibration
Vibration resistance
Malfunction shock
Shock resistance
E5CD
E5ED
Weight
E5CD-B
E5ED-B
Degree of protection
Memory protection
*1
The indication accuracy of K, T, and N thermocouples at a temperature of −100°C or less is ±2°C ±1 digit maximum.
The indication accuracy of U and L thermocouples is ±2°C ±1 digit maximum.
The indication accuracy of B thermocouples at a temperature of 400°C or less is not specified.
The indication accuracy of B thermocouples at a temperature of 400 to 800°C is ±3°C maximum.
The indication accuracy of R and S thermocouples at a temperature of 200°C or less is ±3°C ±1 digit maximum.
The indication accuracy of C/W thermocouples is (±0.3% of PV or ±3°C, whichever is greater) ±1 digit maximum.
The indication accuracy of PLII thermocouples is (±0.3% of PV or ±2°C, whichever is greater) ±1 digit maximum.
*2
Ambient temperature: −10°C to 23°C to 55°C
Voltage range: −15 to +10% of rated voltage
*3
The unit is determined by the setting of the Integral/Derivative Time Unit parameter.
A-1-3
Rating and Characteristics of Options
Event inputs
Communications
Transfer output
A-1-4
Waterproof Packing
If the Waterproof Packing is lost or damage, order one of the following models.
Y92S-P8 (for DIN 48 × 48)
E5@D Digital Temperature Controllers User's Manual (H224)
50 ms
20 MΩ min. (at 500 VDC)
100 to 240 VAC: 3,000 VAC, 50/60 Hz for 1 min between terminals of different
charge
24 VAC/DC: 3,000 VAC,* 50/60 Hz for 1 min between terminals of different
charge
10 to 55 Hz, 20 m/s
10 to 55 Hz, 20 m/s
2
100 m/s
, 3 times each in X, Y, and Z directions
2
300 m/s
, 3 times each in X, Y, and Z directions
Approx. 120 g
Approx. 210 g
Approx. 120 g
Approx. 210 g
Front panel: IP66, rear case: IP20, terminals: IP00
Non-volatile memory (number of writes: 1,000,000)
Contact Input
ON: 1 kΩ max., OFF: 100 kΩ min.
Non-contact Input
ON: Residual voltage 1.5 V max.; OFF: Leakage current 0.1 mA max.
Transmission path: RS-485: Multidrop
Communications method: RS-485 (2-wire, half duplex)
Synchronization: Start-stop
Protocol: CompoWay/F or Modbus
Baud rate: 9.6, 19.2, 38.4,57.6, or 115.2 kbps
Current output: 4 to 20 mA DC, Load: 500 Ω max., Resolution: 10,000, Accuracy: ±0.3% FS
Linear voltage output: 1 to 5 VDC, Load: 1 kΩ min., Resolution: 10,000, Accuracy: ±0.3% FS
2
for 10 min each in X, Y and Z directions
2
for 2 hr each in X, Y, and Z directions
Adapter: Approx. 10 g
Terminal cover: Approx. 0.5 g
each
Adapter: Approx. 4 g × 2
Terminal Cover: Approx. 1 g each
Adapter: Approx. 10 g
---
Adapter: Approx. 4 g × 2
---
Y92S-P9 (for DIN 48 × 96)
A Appendices
A
A - 5

Advertisement

Table of Contents
loading

Table of Contents