A Appendices
cp
Control Period (Heating)
20
M
c-cp
Control Period (Cooling)
20
M
orev
Direct/Reverse Operation
or-r
M
alt1
Alarm 1 Type
2
M
Alarm 1
alh1
Hysteresis
0.2
M
alt2
Alarm 2 Type
2
M
Alarm 2
alh2
Hysteresis
0.2
M
Alarm 3 Type
alt3
2
M
Alarm 3
alh3
Hysteresis
0.2
M
alt4
Alarm 4 Type
2
M
Alarm 4
alh4
Hysteresis
0.2
M
o1st
Control Output 1
4-20
Signal
M
ev-1
Event Input
Assignment 1
msp0
M
Event Input
ev-2
Assignment 2
stop
M
ev-3
Event Input
Assignment 3
none
M
ev-4
Event Input
Assignment 4
none
M
sqr
Extraction of Square
Root Enable
off
M
p-on
Operation After Power ON
cont
M
bar
Bar Display Data
ct1
M
barh
Bar Display Scaling
Upper Limit
50.0
M
barl
Bar Display Scaling
Lower Limit
0.0
M
Move to Advanced
amov
Function Setting
LevelDisplayed when
0
initial setting/communica-
M
tions protect is set to 0.
Move by setting password (−169).
A - 44
Monitor/Setting Item Level
S
Monitor/Setting
25
Monitor/Setting
Item Display 1
Item Display 2
0
Note: The monitor/setting items to be displayed is set in the Monitor/Setting Item 1 to 5 parameters (advanced function setting level).
Press the O Key
for at least 1 s.
Advanced Function Setting Level
init
Parameter Initialization
off
M
Number of Multi-SP
mspu
Points
off
M
SP Ramp Time Unit
spru
m
M
rest
Standby Sequence
Reset
a
M
sb1n
Auxiliary Output 1
Open in Alarm
n-o
M
Auxiliary Output 2
sb2n
Open in Alarm
n-o
M
Auxiliary Output 3
sb3n
Open in Alarm
n-o
M
sb4n
Auxiliary Output 4
Open in Alarm
n-o
M
HB ON/OFF
hbu
on
M
Heater Burnout Latch
hbl
off
M
Heater Burnout
hbh
Hysteresis
0.1
M
α
alfa
0.65
M
tidu
Integral/Derivative
Time Unit
1
M
at-g
AT Calculated Gain
MASK8
0.8
M
at-h
AT Hysteresis
0.8
M
MASK8
lcma
Limit Cycle MV
20.0
Amplitude
MASK8
M
Moving Average Count
mav
* The default is 8 for models
8
other than the E5@C-@-0@.
M
ret
Automatic Display
Return Time
off
M
brgt
Display Brightness
MASK8
3
M
a1lt
Alarm 1 Latch
off
M
S
S
Monitor/Setting
Item Display 3
a2lt
lbab
Alarm 2 Latch
off
3.0
M
M
out1
a3lt
Alarm 3 Latch
o
off
M
M
out2
a4lt
Alarm 4 Latch
none
off
M
M
sub1
prlt
Move to Protect Level
alm1
Time
3
M
M
sub2
cjc
Cold Junction
alm2
Compensation
on
Method
M
M
sub3
a1on
Alarm 1 ON Delay
alm3
0
M
M
sub4
a2on
alm4
Alarm 2 ON Delay
0
M
M
alma
a3on
49
Alarm 3 ON Delay
0
M
M
t-u
a4on
Alarm 4 ON Delay
m
0
M
M
alsp
a1of
Alarm 1 OFF Delay
sp-m
0
M
M
manl
a2of
off
Alarm 2 OFF Delay
0
M
M
pvrp
a3of
20
Alarm 3 OFF Delay
0
M
M
hctm
0
a4of
Alarm 4 OFF Delay
0
M
M
ompw
mant
1.0
Manual Output Method
hold
M
M
pf
Manual MV Initial Value
mani
shft
MASK8
M
M
0.0
M
pfd1
rt
1
RT
MASK8
off
M
M
pfd2
HS Alarm Use
hsu
0
on
M
M
pfd3
hsl
HS Alarm Latch
0
off
M
M
pfd4
HS Alarm Hysteresis
hsh
0
0.1
M
M
pfd5
lba
LBA Detection Time
0
0
M
M
spd1
lbal
LBA Level
1
8.0
M
M
E5@D Digital Temperature Controllers User's Manual (H224)
S
Monitor/Setting
Monitor/Setting
Item Display 4
Item Display 5
LBA Band
spd2
PV/SP No. 2 Display
Selection
0
M
pvst
PV Status Display
Control Output 1
Assignment
Function
off
M
svst
SV Status Display
Control Output 2
Assignment
Function
off
M
Display Refresh
d.ref
Auxiliary Output 1
Period
Assignment
0.25
M
LCT Cooling Output
Llcmt
Auxiliary Output 2
Minimum ON Time
Assignment
0.2
M
Adaptive Control
a-dv
Auxiliary Output 3
Operation Possible
Assignment
50.0
Deviation
M
System Fluctuation
a-sd
Auxiliary Output 4
Reference Deviation
15.0
Assignment
M
Automatic Filter
fasp
Integrated Alarm
Adjustment Seal Period
Assignment
2.0
M
Automatic Filter
fahp
Adjustment Hunting
Soak Time Unit
200
Monitor Period
M
Water-cooling
w-ic
Alarm SP Selection
Proportional Band
1.70
MASK8
Increase Constant
M
w-dc
Water-cooling
Manual MV
Proportional Band
MASK8
Limit Enable
0.90
Decrease Constant
M
Power ON Time Monitor
pwtm
PV Rate of Change
''0
Calculation Period
M
Ambient Temperature
abtm
Monitor
Heating/Cooling
25
Tuning Method
M
Control Output 1
ra1m
Minimum Output
ON/OFF Count Monitor
0
ON/OFF Band
M
Control Output 2
ra2m
PF Setting
ON/OFF Count Monitor
0
M
rac
ON/OFF Counter Reset
Monitor/Setting Item 1
0
MASK8
M
pmst
Parameter Mask Setting
Monitor/Setting Item 2
off
MASK8
M
cmov
Move to Calibration
Monitor/Setting Item 3
0
Level
MASK8
MASK8
M
Monitor/Setting Item 4
MASK8
Monitor/Setting Item 5
MASK8
PV/SP No. 1 Display
Selection
* The default is 1 for models
other than the E5@C-@-0@.