Specifications; A-1-1 Ratings - Omron E5*D series User Manual

Digital temperature controllers
Hide thumbs Also See for E5*D series:
Table of Contents

Advertisement

A Appendices
A-1 Specifications
A-1-1
Ratings
Supply voltage
Operating voltage range
E5CD or E5CD-B
Power
consumption
E5ED or E5ED-B
*1
Sensor input
E5CD or E5CD-B
Relay
output
E5ED or E5ED-B
Voltage
Control
E5CD or E5CD-B
output
*3
output 1/2
(for
driving
E5ED or E5ED-B
SSR)
Linear current output
E5CD
Auxiliary
Relay
E5CD-B
output
outputs
E5ED or E5ED-B
Control method
Setting method
Indication method
Other functions
Ambient temperature
Ambient humidity
Storage temperature
Altitude
Recommended fuse
Installation environment
*1
For input setting ranges, refer to A-8 Sensor Input Setting Range, Indication Range, Control Range.
*2
When connecting the ES2-HB/THB, connect it 1:1.
*3
The E5CD or E5CD-B does not have control output 2.
A - 2
100 to 240 VAC, 50/60 Hz
85% to 110% of rated supply voltage
Option number 000, 800: 5.2 VA max.
Other option numbers: 6.5 VA max.
Option number 000, 800: 6.6 VA max.
Other option numbers: 8.3 VA max.
Thermocouple: K, J, T, E, L, U, N, R, S, B, C/W, PLII
Platinum resistance thermometer: Pt100, JPt100
Infrared temperature sensor: 10 to 70°C, 60 to 120°C, 115 to 165°C, 140 to 260°C
*2
Current input
: 4 to 20 mA, 0 to 20 mA (Input impedance: 150 Ω max.)
*2
Voltage input
: 1 to 5 V, 0 to 5 V, 0 to 10 V
SPST-NO, 250 VAC, 3 A (resistive load), electrical life: 100,000 operations
Min. applicable load: 5 V, 10 mA (reference values)
SPST-NO, 250 VAC, 5 A (resistive load), electrical life: 100,000 operations
Min. applicable load: 5 V, 10 mA (reference values)
Output voltage 12 VDC ±20% (PNP), max. load current 21 mA, with short-circuit protection
circuit
Output voltage 12 VDC ±20% (PNP), max. load current 40 mA, with short-circuit protection
circuit
(21 mA if there are two control outputs)
4 to 20 mA DC, 0 to 20 mA DC, Load: 500 Ω max.
Resolution: Approx. 10,000
2 auxiliary outputs
SPST-NO, 250 VAC, 3 A (resistive load),
Electrical life: 100,000 operations, Minimum applicable load: 10 mA at 5 V (reference values)
2 auxiliary outputs
SPST-NO, 250 VAC, 2 A (resistive load),
Electrical life: 100,000 operations, Minimum applicable load: 10 mA at 5 V (reference values)
4 auxiliary outputs
SPST-NO, 250 VAC, 2 A (resistive load),
Electrical life: 100,000 operations, Minimum applicable load: 10 mA at 5 V (reference values)
ON/OFF or 2-PID control (with autotuning)
Digital setting using front panel keys
11-segment digital display, individual indicators, and bar display
Depend on the model
−10 to 55°C (with no condensation or icing), For 3-year warranty: Mounted individually at −10
to 50°C (with no condensation or icing)
25% to 85%
−25 to 65°C (with no condensation or icing)
2,000 m max.
T2A, 250 VAC, time lag, low shut-off capacity
Overvoltage Category II, Pollution Class 2 (EN/IEC/UL 61010-1)
24 VAC, 50/60 Hz/24 VDC
Option number 000, 800: 3.1 VA max./1.6 W
max.
Other option numbers: 4.1 VA max./2.3 W max.
Option number 000, 800: 4.1 VA max./2.3 W
max.
Other option numbers: 5.5 VA max./3.2 W max.
*5
(Input impedance: 1 MΩ min.)
E5@D Digital Temperature Controllers User's Manual (H224)