Parameter name
Manual Output
Method
Manual MV Initial
*2
Value
Manual MV Limit
MASK8
Enable
*1
A mask is set to this parameter.
Refer to 5-12 Hiding and Displaying Parameters.
*2
If the Manual MV Limit Enable parameter is set to ON, this value will be between the MV upper limit and the
MV lower limit.
Note: Refer to 5-18 Output Adjustment Functions for information on the order of priority for the MV.
 Moving to the Manual Control Level
• Moving with a Key Operation
• When the O Key is pressed for at least 3 seconds in the Operation Level's auto/manual switching
display*, the Manual Mode will be entered and the Manual Control Level will be displayed. It is not
possible to move to any displays except for the PV/MV parameter during manual operation. Press
the O Key for at least one second from the PV/MV parameter display in Manual Control Level to
return to Automatic Mode and display the top parameter in the Operation Level.
*
The Auto/Manual Switch parameter is masked (not displayed) by default. To display it, refer to 5-12 Hiding and
Displaying Parameters.
• Using the PF Key to Move to the Manual Control Level
• When the PF Setting parameter is set to A-M (Auto/Manual), pressing the PF Key for at least one
second while in the Adjustment or Operation Level will change the mode to Manual Mode and
move to the Manual Control Level. During manual operation it is not possible to move to any
displays other than PV/MV (Manual MV). Press the S or O Key for at least one second from the
PV/MV display in the Manual Control Level to change the mode to Automatic Mode, move to the
Operation Level, and display the top parameter in the Operation Level.
Note1: Priority of Manual MV and Other Functions
Even when operation is stopped, the manual MV is given priority.
Auto-tuning will stop when Manual Mode is entered.
2: Manual MV and SP Ramp
If operating, the SP ramp function will continue even when Manual Mode is entered.
• Moving to the Manual Control Level with an Event Input
E5@D Digital Temperature Controllers User's Manual (H224)
Display
HOLD
mant
INIT
mani
Standard control: −5.0 to 105.0
Heating/cooling control: −105.0 to 105.0
manl
OFF: Disabled.
ON: Enabled.
Press O key for at least 1 s.
Manual Control Level
25
a-m
20
PV/MV
Press O key for
at least 3 s.
a-m display flashes
if the Key is pressed
for at least 1 s.
Setting range
Operation Level
PV/SP
25
100
M
Auto/Manual Switch
a-m
MASK
M
Multi-SP
m-sp
0
M
5 Advanced Operations
Default
Level
HOLD
Advanced
0.0
Function Setting
Level
OFF
5 - 57
5