6 Parameters
w1 to 8on
w1 to 8of
• ON Delay
When the results of a work bit logic operation is ON, the work bit is turned ON after the
time specified in the parameter elapses.
Function
• OFF Delay
When the results of a work bit logic operation is OFF, the work bit is turned OFF after the
time specified in the parameter elapses.
Setting
*
 Related Parameters
See
See
Auxiliary Output 1 to 4 Assignment (Advanced Function Setting Level): Page 6-81
plcm
• The Communications Monitor parameter displays the communications cycle time of the
E5@D.
• If communications are not possible with the PLC, c.err is displayed. When
Function
communications are restored, the cycle time is displayed again.
Normal: 0 to 9999 ms, If 9999 ms is exceeded: ]]]]
Setting
Error: c.err
Also refer to the E5
information on communications.
6 - 36
000
Work Bit 1 to 8 ON Delay
Work Bit 1 to 8 OFF Delay
Setting range
0 to 9999
Seconds*
The unit can be changed to minutes on the CX-Thermo Logic
Operation Editor Setting Window.
Communications Monitor
Monitoring range
@
D Digital Controllers Communications Manual (Cat. No. H225) for
The work bit operation type must not be set to OFF.
000
Unit
Default
0
Communications must be supported.
The Protocol Setting parameter must be set to Host
Link (FINS) or the MC Protocol.
E5@D Digital Temperature Controllers User's Manual (H224)