Omron E5*D series User Manual page 297

Digital temperature controllers
Hide thumbs Also See for E5*D series:
Table of Contents

Advertisement

Advanced Function Setting Level
Page
Parameter
init
6-64
Initialization
off
M
mspu
6-64
Number of
Multi-SP Points
off
M
SP Ramp Time
spru
6-64
Unit
m
M
rest
Standby
6-65
Sequence
a
Reset
M
Auxiliary Output
sb1n
6-66
1 Open in Alarm
n-o
M
Auxiliary Output
sb2n
6-66
2 Open in Alarm
n-o
M
sb3n
Auxiliary Output
6-66
3 Open in Alarm
n-o
M
Auxiliary Output
sb4n
6-66
4 Open in Alarm
n-o
M
hbu
HB ON/OFF
6-66
on
M
Heater Burnout
hbl
6-67
Latch
off
M
Heater Burnout
6-67
hbh
Hysteresis
0.1
M
α
alfa
6-68
0.65
M
Integral/Derivative
tidu
6-68
Time Unit
1
M
at-g
AT Calculated
6-69
Gain
MASK8
0.8
M
AT Hysteresis
at-h
6-69
MASK8
0.8
M
Limit Cycle MV
lcma
6-69
Amplitude
MASK8
20.0
M
Moving Average
mav
6-70
Count
*1
off
M
Automatic
ret
6-70
Display Return
off
Time
M
Display
brgt
6-70
Brightness
MASK8
3
M
6-71
a1lt
Alarm 1 Latch
off
M
*1
The default value for the E5D--8 is 8.
*2
The default value for the E5D--8 is 1.
E5@D Digital Temperature Controllers User's Manual (H224)
Page
Alarm 2 Latch
a2lt
6-71
off
M
Alarm 3 Latch
a3lt
6-71
off
M
a4lt
Alarm 4 Latch
6-71
off
M
Move to Protect
prlt
6-72
Level Time
3
M
Cold Junction
cjc
6-72
Compensation
on
Method
M
Alarm 1 ON
a1on
6-73
Delay
0
M
6-73
Alarm 2 ON
a2on
Delay
0
M
Alarm 3 ON
a3on
6-73
Delay
0
M
Alarm 4 ON
a4on
6-73
Delay
0
M
Alarm 1 OFF
a1of
6-74
Delay
0
M
Alarm 2 OFF
a2of
6-74
Delay
0
M
a3of
Alarm 3 OFF
6-74
Delay
0
M
Alarm 4 OFF
a4of
6-74
Delay
0
M
Manual Output
mant
6-74
Method
hold
M
mani
Manual MV Initial
6-75
Value
0.0
M
RT
rt
MASK8
6-76
off
M
HS Alarm Use
hsu
6-76
on
M
HS Alarm Latch
hsl
6-77
off
M
HS Alarm
hsh
6-77
Hysteresis
0.1
M
6-78
LBA Detection
lba
Time
0
M
Page
LBA Level
lbal
6-78
8.0
M
6-79
lbab
LBA Band
3.0
M
Control Output 1
out1
6-80
Assignment
o
M
Control Output 2
out2
6-80
Assignment
none
M
Auxiliary Output 1
sub1
6-81
Assignment
alm1
M
sub2
Auxiliary Output 2
6-81
Assignment
alm2
M
Auxiliary Output 3
sub3
6-81
Assignment
alm3
M
Auxiliary Output 4
sub4
6-81
Assignment
alm4
M
Integrated Alarm
alma
6-82
Assignment
49
M
Soak Time Unit
6-83
t-u
m
M
Alarm SP
6-83
alsp
Selection
MASK8
sp-m
M
Manual MV Limit
manl
6-84
Enable
MASK8
off
M
PV Rate of
pvrp
6-84
Change Calculation
20
Period
M
Heating/Cooling
hctm
6-85
Tuning Method
0
M
Minimum Output
ompw
6-85
ON/OFF Band
1.0
M
PF Setting
pf
6-86
shft
M
Monitor/Setting
6-87
pfd1
Item 1
MASK8
1
M
Monitor/Setting
pfd2
6-87
Item 2
MASK8
0
M
Monitor/Setting
6-87
pfd3
Item 3
MASK8
0
M
pfd4
Monitor/Setting
6-87
Item 4
MASK8
0
M
6 Parameters
Page
Monitor/Setting
pfd5
6-87
Item 5
MASK8
0
M
PV/SP No. 1
6-88
spd1
Display Selection
4
*2
M
PV/SP No. 2
spd2
6-88
Display Selection
0
M
pvst
PV Status
6-89
Display Function
off
M
SV Status
svst
6-90
Display Function
off
M
Display Refresh
d.ref
6-90
Period
0.25
M
LCT Cooling
Llcmt
6-91
Output Minimum
0.2
ON Time
M
Adaptive Control
a-dv
6-91
Operation
50.0
Possible Deviation
M
System Fluctuation
6-92
a-sd
Reference Deviation
15.0
M
Automatic Filter
fasp
6-92
Adjustment Seal
2.0
Period
M
Automatic Filter
fahp
6-92
Adjustment Hunting
200
Monitor Period
M
Water-cooling
w-ic
6-93
Proportional Band
1.70
Increase Constant
M
Water-cooling
w-dc
6-94
Proportional Band
0.90
Decrease Constant
M
Power ON Time
pwtm
6-94
Monitor
''0
M
Ambient
abtm
6-94
Temperature
25
Monitor
M
Control Output 1
ra1m
6-95
ON/OFF Count
0
Monitor
M
Control Output 2
ra2m
6-95
ON/OFF Count
0
Monitor
M
ON/OFF Counter
rac
6-95
Reset
0
M
Parameter Mask
6-95
pmst
Setting
off
M
Move to
cmov
6-96
Calibration Level
0
MASK8
M
6 - 63
6