A.2 Three-Phase 200 V Class Drives
Item
CIMR-T 2A
Maximum Applicable Motor
Capacity (kW)
<1>
Input Current (A)
<2>
Rated Voltage
Rated Frequency
Input
Allowable Voltage Fluctuation
Allowable Frequency Fluctuation
Input Power (kVA)
Rated Output Capacity
(kVA)
<4>
Rated Output Current
(A)
Output
Overload Tolerance
Carrier Frequency
Maximum Output Voltage (V)
Maximum Output Frequency (Hz)
<1> The motor capacity (kW) refers to a Yaskawa 4-pole motor. The rated output current of the drive output amps should be equal to or greater than
the motor rated current.
<2> Assumes operation at the rated output current. Input current rating varies depending on the power supply transformer, input reactor, wiring
connections, and power supply impedance.
<3> DC is not available for UL/CE standards.
<4> Rated motor capacity is calculated with a rated output voltage of 220 V.
<5> Carrier frequency is set to 2 kHz. Current derating is required in order to raise the carrier frequency.
<6> Carrier frequency can be increased up the 8 kHz while keeping this current rating. Higher carrier frequency settings require derating.
<7> Carrier frequency can be increased up the 5 kHz while keeping this current rating. Higher carrier frequency settings require derating.
<8> User-adjustable
YASKAWA ELECTRIC SIEP C710616 30B YASKAWA AC Drive T1000A Technical Manual
Table A.2 Power Ratings (Three-Phase 200 V Class)
0004 0006 0010 0012 0021 0030 0040 0056 0069 0081 0110 0138 0169 0211 0250 0312 0360 0415
HD Rating
0.55
1.1
1.5
2.2
ND Rating
0.75
1.1
2.2
3
HD Rating
2.9
5.8
7.5
11
ND Rating
3.9
7.3
10.8
13.9
HD Rating
1.3
2.2
4.1
5.8
ND Rating
2.2
3.1
5.8
7.8
1.2
1.9
3
4.2
HD Rating
<6>
<6>
<6>
<6>
ND Rating
1.3
2.3
3.7
4.6
<5>
3.2
5
8
11
HD Rating
<6>
<6>
<6>
<6>
ND Rating
3.5
6
9.6
12
<5>
A.2 Three-Phase 200 V Class Drives
Specification
4.0
5.5
7.5
11
15
18.5
5.5
7.5
11
15
18.5
22
18.9
28
37
52
68
80
24
37
52
68
80
96
Three-phase 200 to 240 Vac 50/60 Hz/270 to 340 Vdc
-15 to 10%
±5%
9.5
14
18
27
36
44
14
18
27
36
44
52
6.7
9.5
12.6
17.9
23
29
<6>
<6>
<6>
<6>
<6>
<6>
8
11.4
15.2
21
26
31
17.5
25
33
47
60
75
<6>
<6>
<6>
<6>
<6>
<6>
21
30
40
56
69
81
HD Rating: 150% of rated output current for 60 s
(Derating may be required for applications that start and stop frequently)
ND Rating: 120% of rated output current for 60 s
1 to 15 kHz
<8>
Three-phase 200 to 240 V (proportional to input voltage)
400 Hz
<8>
22
30
37
45
55
75
30
37
45
55
75
90
82
111
136
164
200
271
111
136
164
200
271
324
<3>
37
51
62
75
91
124
51
62
75
91
124
148
32
44
55
69
82
108
<6>
<6>
<7>
<7>
<7>
<7>
42
53
64
80
95
119
85
115
145
180
215
283
<6>
<6>
<7>
<7>
<7>
<7>
110
138
169
211
250
312
1 to 10 kHz
<8>
90
110
110
110
324
394
394
471
148
180
180
215
132
158
<7>
<5>
137
158
346
415
<7>
<5>
360
415
A
353