Making Control Panel Gpi Output Settings - Sony MVS-8000X SystemMVS-7000X System User Manual

Multi format switcher system with ccp-8000 series center control panel
Table of Contents

Advertisement

Carrying out level settings
To set the low level and high level, first set the trigger type
to "Level," then use the following procedure.
1
In the Panel >Device Interface >GPI Input menu,
select the action to be set, and press [H/L Set].
The H/L Set menu appears.
2
Using any of the following methods, select the
settings.
• Press directly on the list in the status area.
• Press the arrow keys to scroll the reverse video
cursor.
• Turn the knob.
Knob Parameter Adjustment
1
No
Signal format/
screen aspect
ratio selection
3
To apply the selection made in step 2 when the input
is the GPI high level, press [H Set]. To apply the
selection made in step 2 when the input is low, press
[L Set].
This confirms the setting, which appears in the status
area.
To set the level for the format converter
1
Set "Action" to "System Format" in step 5 of "Making
Control Panel GPI Input Settings" (page 597).
The format converter list appears.
2
Select the format converter that you want to set from
the list.
3
In the <FC Input/Output> group, press [H Set] or [L
Set] to set the high level or low level, respectively.
Making Control Panel GPI Output
Settings
1
In the Panel >Device Interface menu, press [GPI
Output].
The GPI Output menu appears.
2
Using any of the following methods, select the
settings.
• Press directly on the list in the status area.
• Press the arrow keys to scroll the reverse video
cursor.
• Turn the knob.
Knob Parameter Adjustment
1
3
In the <Trigger Type> group, select the trigger
polarity.
Status: The relay opens/closes or the output goes
Setting values
No Operation: The trigger has no effect on the relay
1 to maximum
value
4
Turning the knobs, select the pulse width and timing to
be set.
Knob Parameter Adjustment
3
4
a) 1: Field 1, 2: Field 2, 3: Any
When " " is selected as the trigger polarity, there is
no Pulse Width setting. When "Status" is selected,
there is no Pulse Width or Timing setting.
5
In the <Source> group, select the action block.
M/E-1 to M/E-5 and P/P: Set an action for the M/E or
Common: Set an action for error status.
6
Using any of the following methods, select the action
to be set.
• Press directly on the list in the status area.
• Press the arrow keys to scroll the reverse video
cursor.
• Turn the knobs.
Knob Parameter Adjustment
2
5
a) Action list when the trigger type is other than "Status"
In M/E-x, the x is the M/E bank number (1 to 5); in DSKx the x is the
DSK number (1 to 8); in Keyx the x is the key number (1 to 8).
When Source is M/E-x: Keyx SS ? Recall, No Action
When Source is P/P: DSKx SS ? Recall, No Action
When Source is Common: KF Run, No Action
Action list when the trigger type is "Status"
Port
Port selection
(Rising Edge): The trigger causes the relay to
open or the output to go high level, and holds this
state for the specified pulse width duration.
(Falling Edge): The trigger causes the relay to
close or the output to go low level, and holds this
state for the specified pulse width duration.
(Any Edge): When a trigger occurs, the relay
opens/closes or the output goes high/low level,
switching state.
high/low level in response to the status.
state or output level.
Pulse
Pulse width
Width
Timing
Output timing
PGM/PST bank.
Action
Action selection
Register number 1 to 4
Reg No
Interfacing With External Devices (Device Interface Menu)
Setting values
1 to 8
Setting values
1 to 60 (fields)
a)
1 to 3
Setting values
1 to maximum
a)
value
b)
599