Example: A value of 9 seconds 23 frames appears as
"9.23" and a value of 10 seconds 1 frame appears as
"10.0."
Setting the transition rate in the Flexi Pad
control block
Notes
When using a simple-type transition control block, you
cannot use the Flexi Pad control block to set the transition
rate.
1
In the M/E bank Flexi Pad control block, press the
[TRANS RATE] button.
The memory recall section display is now ready to
accept the entered transition rate.
Flexi Pad control block (standard type)
2
Enter the desired transition rate with the numeric
keypad.
If required, press the [TC] button to toggle the input
mode (frame input or timecode input).
• Enter a value of up to three digits.
• To cancel the entry, press any of the six buttons in
the leftmost column ([WIPE], [DME], ...) or the
[TRANS RATE] button.
3
Press the [ENTR] button.
This confirms the entry, and the new setting appears in
the transition control block display.
106
Executing a Transition
TRANS RATE button
TC button
ENTR button
Memory recall section
Setting the transition rate in the numeric
keypad control block
TRANS RATE button
Region selection buttons
Numeric keypad control block
1
In the numeric keypad control block, press the
[TRANS RATE] button.
2
Press the region selection button for the M/E or PGM/
PST bank for which you want to set the transition rate,
turning it on.
The numeric keypad control block display now shows
the selected region name and the current transition rate
setting for the region.
3
With the numeric keypad, enter the transition rate.
If required, press the [TC] button to toggle the input
mode (frame input or timecode input).
• Enter a value of up to three digits.
• To clear the entry, press the [CLR] button.
4
Press the [ENTER] button.
This confirms the entry, and the selected region name
and the set transition rate appear in the numeric keypad
control block display.
The transition control block display of the same bank
(M/E or PGM/PST) also shows the setting.
To enter a difference from the current value
After pressing the [+/–] button, enter the difference and
press the [TRIM] button.
To change the sign (+ or –), press the [+/–] button.
Setting the transition rate in the
Multifunction Flexi Pad control block
1
In the Multifunction Flexi Pad control block, press the
[TRANS RATE] button.
Numeric keypad
Display
TC button
ENTER button