Making Control Panel Gpi Output Settings - Sony MVS-3000 System User Manual

Multi format switcher system
Hide thumbs Also See for MVS-3000 System:
Table of Contents

Advertisement

• As for "Aux ? O'ride Src ??," when "Rising Edge" is
selected, on a rising edge the set AUX bus input is used.
On a falling edge, the original state of the cross-point is
restored. If the GPI trigger is applied repeatedly at short
intervals (0.5 second or less), the cross-point switching
may not be carried out correctly. In this case, apply the
GPI trigger again.
Carrying out level settings
To set the low level and high level, first set the trigger type
to "Level," then use the following procedure.
1
In the Engineering Setup >Panel >Device Interface
>GPI Input menu (7325.1), select the action to be set,
and press [H/L Set].
The H/L Set menu (7325.2) appears.
2
Select the setting.
3
To apply the selection made in step 2 when the input
is the GPI high level, press [H Set]. To apply the
selection the input is low, press [L Set].
To set the level for the format converter
1
Set "System Format" for "Action" using the same
operation in Step 5 of
"Making Control Panel GPI
Input Settings" (1 p.
230).
The format converter list appears.
2
Select the format converter that you want to set from
the list.
3
In the <FC Input/Output> group, press [H Set] or [L
Set] to set the high level or low level, respectively.
Making Control Panel GPI Output
Settings
You can set the GPI output ports and trigger type, and
make the action settings.
1
Open the Engineering Setup >Panel >Device Interface
>GPI Output menu (7325.3).
2
Select the setting.
3
In the <Trigger Type> group, select the trigger type.
(Rising Edge): The trigger causes the relay
contacts to be open-circuit or drives the output
high, and holds this state for the specified pulse
width.
(Falling Edge): The trigger causes the relay
contacts to be shorted or drives the output low, and
holds this state for the specified pulse width.
(Any Edge): Each time the trigger occurs, the
relay contacts are alternately closed or opened, or
the output is switched between high and low.
Status: Depending on the status, the relay contacts are
closed or opened, or the output is switched
between high and low.
No Operation: The trigger has no effect on the relay
state or output level.
4
Select the pulse width and timing.
No.
Parameter
Adjustment
3
Pulse Width Pulse width
4
Timing
Output timing
a) 1: Field 1, 2: Field 2, 3: Any
When "
" is selected as the trigger polarity, there is
no Pulse Width setting. When "Status" is selected,
there is no Pulse Width or Timing setting.
5
In the <Source> group, select the action block.
M/E-1 and P/P: Sets an action for the M/E or PGM/
PST bank.
Common: Sets an action for error status.
6
Select the action to set.
7
Press [Action Set] to confirm the action selection.
Selectable actions for various trigger types
• When the trigger type is other than "Status"
(The x in M/E-x is the M/E bank number, the x in DSKx
is the DSK number, and the x in Keyx is the key
number).
When Source is M/E-x: Keyx SS ? Recall, No Action
When Source is P/P: DSKx SS ? Recall, No Action
When Source is Common: KF Run, No Action
• When the trigger type is "Status"
(The x in M/E-x is the M/E bank number, the x in DSKx
is the DSK number, and the x in Keyx is the key
number).
When Source is M/E-x: Keyx SS ? Recall, Keyx On, No
Action
When Source is P/P: DSKx SS ? Recall, DSKx On, No
Action
When Source is Common: Error Make, Error Break,
Keep Break, Keep Make, PREFS1, PREFS2,
PREFS3, PREFS4, PREFS5, PREFS6, PREFS7,
PREFS8, PREFS9, PREFS10, PREFS11, PREFS12,
PREFS13, PREFS14, PREFS15, PREFS16, Device
Recording, No Action
a)
Interfacing with External Devices
231

Advertisement

Table of Contents
loading