Sony MVS-8000X SystemMVS-7000X System User Manual page 244

Multi format switcher system with ccp-8000 series center control panel
Table of Contents

Advertisement

Notes
When [Mask 2] is selected in the Secondary CCR
menu, linked to this setting it automatically changes
from [Mask 2] to [Mask 1].
3
Press [Mask1 Adjust].
The Mask1 Adjust menu appears.
4
In the <Mask Source> group, select the mask source.
Box: signal from dedicated box generator
Pattern: signal from dedicated pattern generator
5
Depending on the selection in step 3, adjust the
following parameters.
When Box is selected
Knob Parameter Adjustment
1
Top
2
Left
3
Right
4
Bottom
5
Soft
When Pattern is selected
Knob Parameter Adjustment
1
Size
2
Soft
5
Pattern
For the pattern selection, you can also press [Mask Ptn
Select] in the Mask1 Adjust menu, then use the Mask
Ptn Select menu.
Press any of the displayed patterns (standard wipe
patterns 1 to 24) to select it, then you can adjust the
following parameters.
Knob Parameter Adjustment
1
Size
2
Soft
6
When selecting the pattern as a mask source, set the
pattern modifiers as required.
244
Color Corrector Functions
Setting values
–100.00 to +100.00
Top position
–100.00 to +100.00
Left position
–100.00 to +100.00
Right
position
–100.00 to +100.00
Bottom
position
Degree of
0.00 to 100.00
softness of
box
Setting values
Pattern size
0.00 to 100.00
Degree of
0.00 to 100.00
softness of
pattern edge
Pattern
1 to 24
number
Setting values
Pattern size
0.00 to 100.00
Degree of
0.00 to 100.00
softness of
pattern edge
When turning [Position] on and setting the pattern
position
Knob Parameter Adjustment Setting values
1
Position H
Horizontal
position
2
Position V
Vertical
position
a) See "Setting the wipe position (Positioner)" (page 169).
When turning [Multi] on and replicating the same
pattern
Knob Parameter Adjustment
1
H Multi
Number of
repetitions of
pattern
horizontally
2
V Multi
Number of
repetitions of
pattern
vertically
3
Invert Type Replication
layout
a) See "Setting the wipe pattern replication (Multi)" (page 171).
When turning [Aspect] on and setting the aspect
ratio of the pattern
Knob Parameter Adjustment Setting values
Aspect ratio –100.00 to +100.00
1
Aspect
a) See "Setting the wipe pattern aspect ratio (Aspect ratio)" (page 171).
When turning the [Angle] on in the <Rotation>
group and slanting the pattern
Knob Parameter Adjustment Setting values
1
Angle
Angle of
pattern
rotation
a) See "Angle" (page 170).
When turning [Speed] on in the <Rotation> group
and rotating the pattern at a fixed rate
Knob Parameter Adjustment Setting values
1
Speed
Rotation
rate of
pattern
a) See "Speed" (page 170).
7
To invert the mask source, return to the Primary CCR
menu and press [Pri/Sec Mask Invrt], turning it on.
a)
–200.00 to +200.00
–200.00 to +200.00
a)
Setting values
1 to 63
1 to 63
a)
1 to 4
a)
–100.00 to +100.00
a)
a)
–100.00 to +100.00

Advertisement

Table of Contents
loading

Table of Contents