Point: Point light source. The position can be set.
Line: Line light source. The position and angle can be
set.
Whole: Non-directional light source which
illuminates the whole image (no settings).
5
According to the selected light source type, set the
following parameters.
When you selected Parallel
Knob Parameter Adjustment
1
Longitude
Longitude
2
Latitude
Latitude
a) Minus moves counterclockwise, plus moves clockwise.
When you selected Point
• SD format
Knob Parameter Adjustment
1
X
Movement in
X-axis direction
Movement in
2
Y
Y-axis direction
Movement in
3
Z
Z-axis direction
a) Minus moves left, plus moves right.
b) Minus moves down, plus moves up.
c) Minus moves forward, plus moves deeper.
• HD format
Knob Parameter Adjustment
Movement in
1
X
X-axis direction
2
Y
Movement in
Y-axis direction
3
Z
Movement in
Z-axis direction
a) Minus moves left, plus moves right.
b) Minus moves down, plus moves up.
c) Minus moves forward, plus moves deeper.
When you selected Line
• SD format
Knob Parameter Adjustment
Movement in
1
X
X-axis direction
2
Y
Movement in
Y-axis direction
3
Z
Movement in
Z-axis direction
4
Longitude
Longitude
a) Minus moves left, plus moves right.
b) Minus moves down, plus moves up.
c) Minus moves forward, plus moves deeper.
d) Minus moves counterclockwise, plus moves clockwise.
• HD format
Knob Parameter Adjustment
1
2
3
4
Setting values
–8.00 to +8.00
a)
a) Minus moves left, plus moves right.
–8.00 to +8.00
b) Minus moves down, plus moves up.
c) Minus moves forward, plus moves deeper.
d) Minus moves counterclockwise, plus moves clockwise.
6
In the <Axis Select> group, select the coordinate space
in which to place the light source.
Source: Place the light source in the source coordinate
Setting values
–6.00 to +6.00
a)
Target: Place the light source in the target coordinate
b)
–6.00 to +6.00
c)
–6.00 to +6.00
For details of the coordinate space in which to place
the light source, see "Linking and unlinking image and
spotlight" (page 337).
To set a test sphere
1
In the Light 1 menu, press [Test Sphere], turning it on.
Setting values
–24.00 to
A test sphere effect appears on the surface of the
a)
+24.00
image.
–24.00 to
2
b)
Adjust the following parameter.
+24.00
–24.00 to
c)
+24.00
Knob Parameter Adjustment Setting values
5
a) Light appears from Z direction. At –100.00 the light goes deepest, at
To select the lighted area
In the <Area Select> group, select one of the following.
Setting values
FRGD: The light strikes the image foreground.
–6.00 to +6.00
a)
BKGD: The light strikes the image background.
Both: The light strikes both foreground and background.
b)
–6.00 to +6.00
For more information about the lighted area, see
"Selecting the lighted area" (page 337).
–6.00 to +6.00
c)
–8.00 to +8.00
d)
Notes
• If you select [Multiply] in the <Fill Blending Mode>
group of the Light Color Adjust menu (see page 343),
Movement in
X
X-axis direction
Movement in
Y
Y-axis direction
Movement in
Z
Z-axis direction
Longitude
Longitude
space. The spotlight moves when the image
moves.
space. The spotlight does not move, even when the
image moves.
Amp
Distance of
light
+100.00 the whole image is lit like a flat effect.
Applying Special Effects (Lighting and Recursive Effects)
Setting values
–24.00 to
a)
+24.00
–24.00 to
b)
+24.00
–24.00 to
c)
+24.00
–8.00 to +8.00
d)
a)
–100.00 to +100.00