using the Wipe menu or DME Wipe menu to access the
Edge/Direction menu for the M/E or PGM/PST bank.
Notes
• A pattern limit only applies when a wipe or DME wipe
is selected as the transition type.
• A pattern limit cannot be applied to an independent key
transition (see page 113).
• In multi-program mode, pattern limits can be used only
when the background transition type is a wipe or DME
wipe. If a key is selected for the next transition, the
pattern limit settings are reflected in the wipe or DME
wipe selected for the background transition type.
Transition control block (standard type)
Setting the pattern limit with the fader
lever
1
Move the fader lever to the position corresponding to
a particular pattern size.
• First make sure that the [PTN LIMIT] button is off.
• To check the pattern size on the preview monitor,
first press the [TRANS PVW] button, to select the
transition preview mode (see page 112).
2
Press the [LIMIT SET] button.
This sets the current fader lever position as the pattern
limit.
108
Executing a Transition
LIMIT SET button
PTN LIMIT button
TRANS PVW button
Setting the pattern limit by a menu
operation
1
When a wipe is selected as the transition type, in the
M/E or PGM/PST menu, select first VF5 'Wipe,' then
HF4 'Edge/Direction.'
When a DME wipe is selected as the transition type, in
the M/E or PGM/PST menu, select first VF6 'DME
Wipe,' then HF4 'Edge/Direction.'
The Edge/Direction menu appears.
2
Press the [Pattern Limit] button, turning it on.
3
Turn the knobs to adjust the following parameters.
Knob Parameter Adjustment
1
Pattern
Pattern limit
Limit
a) 0.00%: Executing the transition does not change the video output at
all.
b) 100.00%: The transition is the same as when no pattern limit is set,
but the cross-point button selections of the background A and B
buses do not interchange when the transition completes.
Executing a pattern limit transition
1
Press the [PTN LIMIT] button, turning it on.
The button you pressed lights amber.
2
Carry out the transition.
The transition progresses as far as the set pattern limit.
Even if the transition completes, the cross-point button
assignments of the background A and B buses do not
interchange.
3
Carry out the transition once again.
The status before the previous transition is restored.
To cancel the pattern limit
To cancel the pattern limit after completion of step 3 in the
previous procedure, press the [PTN LIMIT] button,
turning it off.
If after carrying out step 2 in the previous procedure, the
pattern limit has been reached, carry out the following
procedure.
1
Press the [PTN LIMIT] button.
The button you pressed lights green.
2
Carry out the transition.
The [PTN LIMIT] button goes off, and the pattern
limit state is released.