Step
Action and questions
Check the clamp drive motor for
3
proper operation.
When performing
motor tests, ensure
that all cover and
door interlock
switches are
overridden.
1. Enter the Diagnostics Menu.
2. Touch MOTOR TESTS.
3. Touch FINISHER MOTOR
TESTS.
4. Touch Media eject clamp
motor (clamp).
5. Touch Media eject clamp
motor (unclamp).
Does the above component
operate properly?
Check the clamp drive motor for
4
proper connection.
Is the above component
properly connected?
Check the eject shaft roll motor
5
for proper operation.
When performing
motor tests, ensure
that all cover and
door interlock
switches are
overridden.
1. Enter the Diagnostics Menu.
2. Touch MOTOR TESTS.
3. Touch FINISHER MOTOR
TESTS.
4. Touch Media eject motor
(forward).
5. Touch Media eject motor
(reverse).
Does the above component
operate properly?
Check the eject shaft roll motor
6
for proper connection.
Is the above component
properly connected?
Yes
Go to step 5.
Replace the clamp drive motor.
Go to
"Clamp drive motor
removal" on page
4-340.
Go to step 7.
Replace the eject shaft roll motor.
Go to
"Media eject motor
assembly removal" on
page
4-369.
7558-xxx
No
Go to step 4.
Replace the connection.
Go to step 6.
Replace the connection.