Sensor (Punch Waste Box Set) Removal - Lexmark X95 series Service Manual

Hide thumbs Also See for X95 series:
Table of Contents

Advertisement

7558-xxx
Remove the two screws securing the paper guide (C) to the punch unit assembly (B).
8.
Note: Do not remove the harness attached to the paper guide (C).
Turn the paper guide (C) upside down.
9.
Remove the two screws securing the bracket (D) to the paper guide (C).
10.
Remove the bracket (D).
11.
Remove the two connectors from the sensor (punch unit side registration pair) (E).
12.
13.
Release the hooks securing the sensors (punch unit side registration pair) (E) to the bracket (D).
14.
Remove the sensor (punch unit side registration pair) (E).
Note: The two sensors are identical.

Sensor (punch waste box set) removal

Open the finisher front door assembly.
1.
Pull the punch waste box.
2.
Disconnect the connector from the sensor (punch waste box set) (A).
3.
Service Manual
4-400
B
)
C
C
A
D
Connectors
E
D
Connectors