Call Handling Configuration
Programmable Range
DISA data fields:
ACCESS CODE = Range 1-24
DISA Lines DHS = 1-12 programmable range
DISA Lines DHS-E = 1-18 programmable range
DISA DAY COS = Range 0-7
DISA NITE COS = Range 0-7
SERVICE = Never/day/nite/always
TALK TIME = 1/2/3/5/10/15 minutes

EXT Call Forward (ECF)

Description
One CO line in the system may be designated as the External Call Forward (ECF) CO line.
When this CO line rings it is automatically answered by the system and routed to another
CO line where a predetermined telephone number is dialed. These two lines are
connected together in a conference and allowed to remain connected for the duration of
the TALK TIME. ECF programming has four data fields:
INCOMING
OUTGOING
SERVICE
modes of operation.
TALK TIME – The preset time limit of the ECF call. ECF may be disconnected prior to
the expiration of the TALK TIME by the remote party by dialing [0] + [#] at any time
during the ECF call, or [0] + [✳] to extend it.
Default
The
DHS/DHS-E
INCOMING DHS = None
INCOMING DHS-E = None
SERVICE = Never
TALK TIME = 1
Programmable Range
ECF data fields:
INCOMING DHS = 0-12
INCOMING DHS-E = 700-718
SERVICE = Never/day/nite/always
TALK TIME = 1/2/3/5/10/15 minutes.
Is the CO line to be answered by the system.
The CO line to be used by the system for the outgoing call.
Setting that allows the feature to operate only during certain system
DHS requires the Option Module for correct operation of this Feature.
default settings of associated ECF data fields are:
6-25