Call Handling Configuration

Exclusive Hold Time

Calls placed on Exclusive Hold will remain on Exclusive Hold for the duration of this timer.
When the timer expires the holding line will change from Exclusive Hold flash to Recall
Flash and alert the station user with one tone ring over the telephone speaker. When the
timer expires a second time and the CO line remains on hold the station will receive a
second alert tone and the CO line holding condition will change to System Hold so that
any station may access the holding line.
Default
The
DHS/DHS-E
minutes (where 0 is infinite).

Flash Time

Flash is typically used on CO lines that are equipped with special features from the
telephone company such as Call Waiting. Flash may also be used on CO lines connected
to a PBX or to Centrex lines for call transfer on those lines. The Flash time must be set to
coincide with the required timing parameter of the connected line to operate correctly.
Typically a value from 600 to 800 msec is used for these features. A higher flash time may
be set to allow the user to invoke flash to restore dial tone on the connected CO line. This
setting is typically 1.5 sec (1500 msec).
Default
The
DHS/DHS-E
msec) to 1.5 sec (1500 msec).

Reminder Time

The Remind Time can be programmed to alert stations of calls that have been placed on
System Hold at their station. The station that placed a call on System Hold will hear a
reminder tone over the key telephone speaker once each time the Remind Time expires
until the CO Line is answered, or the call is disconnected.
Default
The
DHS/DHS-E

Park Remind

Similar to Remind Time, Park Remind will alert stations of CO lines parked at their location
once each time the Park Remind time expires.
Default
The
DHS/DHS-E
Exclusive Hold Time is set to four minutes, and is variable from 0-8
Flash Time' is set for 0.7 sec (700 msec), and is variable from 0.1 sec (100
Remind Time is set for 30 sec, and is variable from 0/10/30/60/90 sec.
Park Remind is set for 30 sec, and is variable at 30/60/90/120/150/180 sec.