Dialing Specifications; Fcc Registration Numbers; Maximum Cable Length - Vodavi Starplus DHS Technical Manual

Table of Contents

Advertisement

DHS Technical Specification Tables
Digital Key Telephone
(Distance measures in linear ft. of cable from KSU
to DKT.)
Standard SLT
(Distance measures in linear ft. of cable from KSU
to SLT. 2-Port CO Module may be placed anywhere
in between.)
DTMF Dialing mode:
Frequency deviation
Rise time
Duration of DTMF signal
Inter-digit time
VM Port DTMF duration
VM Port Inter-digit time
Pulse Dialing mode:
Pulse dial rate
Pulse Make/Break ratio
For systems configured for Key System operation (each CO
line appears on its own dedicated button).
For systems configured for hybrid operation (CO lines may
be accessed by dial codes and Pool/Loop buttons).
Table 2-6: Maximum Cable Length
Table 2-7: Dialing Specifications
+ 1%
3ms
programmable 50-150ms (70ms default)
programmable 50-150ms (70ms default)
programmable 60-150ms (120ms default)
programmable 60-150ms (120ms default)
10 pulses per second
60/40
Table 2-8: FCC Registration Numbers
26 AWG - (850 ft) 255 m
24 AWG - (1416 ft) 425 m
22 AWG - (1983 ft) 700 m
26 AWG - (650 ft) 195 m
24 AWG - (1133 ft) 340 m
22 AWG - (1586 ft) 476 m
D6XTAI-23085-KF-E
D6XTAI-23086-MF-E
2-19