Hmc Surveillance Error Codes - IBM pSeries 670 Service Manual

Hide thumbs Also See for pSeries 670:
Table of Contents

Advertisement

Error Code Description
B1xx 469E Service processor firmware failure
B1xx 469F Service processor failure
B1xx 8FF0 Informational message
B1xx A2D0 Write operation to the LPAR data area in
NVRAM failed
B1FD 0013 A firmware update has failed because the
update image is invalid. The update was
stopped before any changes were made to the
currently installed firmware
B1FD 0015 Too many firmware update diskettes were
inserted (or the update image was faulty, or not
the right image for the system)
B1FD 0016 Firmware update diskette read error
B1FD 001A Service processor recovery mode update fault
B1FD 001E Service processor recovery mode update fault
B1FD 001F Firmware update diskette bad

HMC Surveillance Error Codes

The HMC surveillance error codes generated only by the HMC are listed in the following table.
Error Code
B301 0001 HMC/partition surveillance fault
Description
Action/
Possible Failing FRU
1. Check for system firmware updates.
2. Reboot the system in slow mode to isolate
a problem in the processor subsystem.
3. Primary I/O book
Location: U1.18-P1-H2
1. Check for system firmware updates.
2. Reboot the system in slow mode to isolate
a problem in the processor subsystem.
3. Primary I/O book
Location: U1.18-P1-H2
No action required.
1. Using the HMC, perform a soft reset on the
partition that reported this error.
2. Using the HMC, perform a hard reset on the
partition that reported this error.
3. If the attempts to reset the partition are not
successful, shut down all partitions, then
remove and reapply AC power to the
system.
4. Reboot the system.
Reset the service processor by activating the
pinhole reset switch on the operator panel.
Flash a valid firmware update image for the
system type and model.
1. Essure that the firmware update image is
correct for the system type and model.
2. Replace the update diskettes with a new set
of firmware update diskettes.
1. The firmware diskette may be faulty. Try
another diskette.
2. Diskette drive
Location: U1.17- D1.
3. Primary I/O book
Location: U1.18-P1-H2.
Reset the service processor by activating the
pinhole reset switch on the operator panel.
Attempt to flash a valid firmware update image
for the system type and model again.
Wrong firmware update diskette. Insert the
correct update diskette.
Replace the update diskette.
Action/ Possible Failing FRU
Contact service support.
Chapter 5. Error Code to FRU Index