Technical Data - KEB COMBIVERT R6-S Instruction Manual

Power supply and regenerative unit
Hide thumbs Also See for COMBIVERT R6-S:
Table of Contents

Advertisement

5.

Technical Data

Unit size
Housing size
Phases
permitted mains forms
Rated voltage
Mains voltage range
Mains frequency
DC voltage range
Regenerative operation
Output rated power
Rated active power
Max. power output
Max. active power
Regenerative rated current
Regenerative DC current
Over load current (E.OL) 60 s
Max. regenerative DC current 60 s
Power supply operation
Input rated power
Rated active power
Max. input power
Max. active power
Rated supply current
DC supply current
Over load current (E.OL) 60 s
Max. DC supply current 60 s
Overload disconnection (E.OL)
Overvoltage switch-off (E.OP)
Output rated voltage
Max. permissible DC link capacity
Max. permissible total load current at precharging
(I_LSF)
I
t Integral of the limiting load of the semiconduc-
2
tor
Max. permissible mains fuse type gR / aR
Perm. gR fuse Siemens Sitor (no delta power system)
Max. permissible DC fuse Siemens Sitor type aR
Short-circuit factor at the connection point (S
Power loss at nominal operating
Max. heat sink temperature
The overload current is specified for 1 minute. The overload cycle is 300 seconds. This corresponds to load class 2
1)
according to EN 60146-01-1.
The current data are based on a fundamental frequency component of g=0.95. The fundamental frequency com-
2)
ponent or the effective value of the input current is dependent on load and line supply conditions. At uncontrolled
B6 converters the phase angle cosφ1 can be set to one, so the value of the fundamental frequency components is
equal to the value of the power factor.
Please contact KEB for higher values.
3)
IT and delta power system after consultation KEB (see also safety instructions, voltage with respect to ground).
4)
Voltage stabilization must be activated at the inverter if a harmonic filter is used.
The units are not short circuit proof without corresponding dimensioned fuses
[V]
[V]
[Hz]
[V
]
DC
Sn
[kVA]
[kW]
[kVA]
[kW]
[A]
[A
]
DC
1)
[A]
[A
]
DC
Sn
[kVA]
[kW]
[kVA]
[kW]
2)
[A]
[A
]
DC
[A]
[A
]
DC
[%]
[V
]
DC
[V
]
DC
3)
[mF]
[A
]
AC
[A
s]
2
[A]
"/S
) or (S
/S
)
kn
n
scp
n
[W]
[°C]
Technical Data
29
P
3
TN, TT
4)
400
305...528 ±0 %
50 / 60 ±2
420...747 ±0 %
346
330
433
413
500
590
625
738
336
310
420
388
485
590
606
738
160
800
540
60 (400 V class) 35 (480 V class)
≤4
40500
670
3NE1447-2
see options
30 < S
" / S
< 350
kn
n
2800
79
GB - 67