Advertisement

Operation of the Unit

5.
Operation of the Unit
5.1

Keyboard

When switching on the KEB COMBIVERT R6-S the value of parameter CP.1 appears.
The function key (FUNC) changes between the parameter
value and parameter number.
With UP (▲) and DOWN (▼) the value of the parameter
number
is
increased/decreased
parameters.
Generally, changes to parameter values are immediately accepted and stored non-volatile. However, with some
parameters, due to their functionality, the adjusted value is not accepted immediately. With these parameters (see
parameter overview) the adjusted value is accepted and stored non-volatile by pressing ENTER.
If an error occurs during operation, then the actual display is overwritten by the error message. The error message
in the display is reset by ENTER.
With ENTER only the error message in the display is reset. The status display (CP.3) still displays
the error. In order to reset the error itself, the cause must be corrected and a power-on reset must be
made. Note: The R6 unit will attempt to reset errors on its own based on the auto reset parameter.
5.2

Operation with PC and programming software COMBIVIS

Instructions for the installation and operation of the programming software COMBIVIS are provided with the
software.
with
changeable
== Error ==>
US - 27