Technical Data - KEB COMBIVERT R6-S Series Instruction Manual

Power supply and regenerative unit
Hide thumbs Also See for COMBIVERT R6-S Series:
Table of Contents

Advertisement

3.

Technical Data

3.
Technical Data
Unit size
Housing size
Phases
permitted mains forms
Rated voltage
Mains voltage range
Mains frequency
DC voltage range
Regenerative operation
Output rated power
Rated active power
Max. power output
Max. active power
Regenerative rated current
Regenerative DC current
Over load current (E.OL) 60 s
Max. regenerative DC current 60 s
Power supply operation
Input rated power
Rated active power
Max. input power
Max. active power
Rated supply current
DC supply current
Overload current (E.OL) 60s
Max. DC supply current 60s
Overload disconnection (E.OL)
Overvoltage switch-off (E.OP)
Output rated voltage
Max. permissible DC link capacity
Max. permissible total load current at precharging (I_
LSF)
I
t Integral of the limiting load of the semiconduc-
2
tor
Max. permissible mains fuse type gR / aR
Permissible mains fuse (no delta power system)
Permissible mains fuse (no delta power system) for UL
Max. permissible DC fuse Bussmann Type aR
Short-circuit factor at the connection point (S
Power loss at nominal operating
Max. heat sink temperature
The values in brackets must be observed when UL approval is required!
*)
Lay two connection cables parallel at supply and regenerative current > 230 A DC.
1)
The overload current is specified for 1 minute. The overload cycle is 300 seconds. This corresponds to duty class 2
2)
EN 2-60146-1.
The current data are based on a fundamental frequency component of g=0.95. The fundamental frequency com-
3)
ponent or the effective value of the input current is dependent on load and line supply conditions. At uncontrolled
B6 converters the phase angle cosφ1 can be set to one, so the value of the fundamental frequency components is
equal to the value of the power factor.
Please contact KEB for higher values.
4)
US - 14
5)
[V]
[V]
[Hz]
[V
]
DC
Sn
[kVA]
[kW]
[kVA]
[kW]
*)
[A]
1)
[A
]
DC
2)
[A]
[A
]
DC
Sn
[kVA]
[kW]
[kVA]
[kW]
*), 3)
[A]
1)
[A
]
DC
[A]
[A
]
DC
[%]
[V
]
DC
[V
]
DC
4)
[mF]
[A
]
AC
[A
s]
2
[A]
Ferraz Shawmut HSJ300, rated 300A / 600Vac
/S
) or (S
/S
)
kn
n
scp
n
[W]
[°C]
25
R
3
TN, TT
400
305...528
50 / 60 ±2
420...747
153
140
230
210
221 (184)
270
331
405
153
140
230
210
221 (184)
270
331
405
160
840
540
50 (400 V class) 35 (480 V class)
≤4
39000
315
Siemens 3NE8731 /
Eaton Bussmann 170M1372 or 170M1422
see options
15 < S
" / S
kn
1300
88
< 350
n

Advertisement