Connection Terminals Of The Power Circuit - KEB COMBIVERT R6-S Series Instruction Manual

Power supply and regenerative unit
Hide thumbs Also See for COMBIVERT R6-S Series:
Table of Contents

Advertisement

4.3.2

Connection terminals of the power circuit

All terminal strips meet the requirements on EN 60947-7-1 (IEC 60947-7-1)
View of power supply and regenerative units
The terminals of a power supply and regenerative unit can be input or output
dependent on the actual operating status (power supply or regeneration). For
standardization, the line side is always regarded as input and the DC voltage
side is always regarded as output.
Equivalent circuit diagram for R6-S in E hous-
L1.2
L2.2
L3.2
Terminals
++, – –
L1.2, L2.2, L3.2 Mains input 3-phase coming from the commutation reactor
Figure 10:
US - 28
ing
Description of terminals at KEB inverters
DC voltage output with starting current limiting for loading the connected
inverters; usable as input for regenerative operation. If inverters with mains
supply of type A1 or A2 (see 4.3.1) are available in the DC bus, these may
be switched to mains only after loading the DC bus. Note the maximum
DC link capacity or decoupling diodes !
Description of the input terminals of the COMBIVERT R6
Equivalent circuit diagram for R6-S in R
housing with internal DC fuses
++
X1B L1
X1C L1
+
X1C L2
X1B L2
--
I_LSF
L1.2
+
L2.2
L3.2
++
--