Operator

6.6
Operator
An operator is necessary as accessories for local or external operation of the COMBIVERT
R6-S. To prevent malfunctions, the COMBIVERT must be brought into nOP status before
connecting/ disconnecting the operator (open control release). When starting the COMBI-
VERT, it is started with the last stored values or factory setting.
Digital operator (part number 00F5060-1000)
Interface operator (part number 00F5060-2000)
x x 5-digit LED Display
x x Operating-/Error display
Normal "LED on"
Error "LED blinks"
- x Interface control
Bus operation "LED on"
x x Double function keyboard
- x X6B HSP5 programming and diagnostic interface
- x X6C RS232/RS485
Only use the operator interface for the serial data transfer to RS232/485. The di-
rect connection, PC to the COMBIVERT is only permissible with a HSP5-special
cable (part number 00F50C0-0001) otherwise it would lead to the destruction of
the PC-interface !
X6C
5 4 3 2 1
5
4
9
8
9 8 7 6
GB - 90
PIN RS485 Signal Meaning
1
2
3
4
3
2
1
5
6
7
6
7
8
9
9-pole Sub-D socket
RS 232 cable
Part number
0058025-001D
Length 3 m
-
-
reserved
-
TxD
Transmission signal RS232
-
RxD
Receive signal RS232
A'
RxD-A Receive signal A RS485
B'
RxD-B Receive signal B RS485
-
VP
Voltage supply +5 V (Imax=50 mA)
C/C'
DGND Data reference potential
A
TxD-A Transmission signal A RS485
B
TxD-B Transmission signal B RS485
3
to the PC
2
5
START
ENTER
F/R
STOP
X6B
C O M B I V E R T
X6C
9-pole Sub-D connector
2
to the operator
3
7
Housing (PE)
FUNC.
SPEED
X6D