Connection of the COMBIVERT R6
4.3.2
Connection terminals of the R6 power circuit
Input voltage
The COMBIVERT R6 in E-housing is suitable for rated voltages of 230 V and
400 V.
View of power supply and regenerative units
The terminals of a power supply and regenerative unit can be input or output
dependent on the actual operating status (power supply or regeneration). For the
standardization of the view the line side is always regarded as input and the DC
voltage side is always regarded as output.
Terminals
++, --
L1.2, L2.2, L3.2 Mains input 3-phase coming from the commutation reactor
Table 8:
GB - 26
L1.2
L2.2
L3.2
Description of terminals at KEB inverters
DC voltage output with starting current limiting for loading the connect-
ed inverters; usable as input for regenerative operation. If inverters with
mains supply of type A1 or A2 (see 4.3.1) are available in the DC bus,
these may be switched to mains only after loading the DC bus. Note the
maximum DC link capacity or decoupling diodes !
Description of the input terminals of the COMBIVERT R6
R6-S in E-housing
++
+
--