Operating Environment Specifi Cations - KEB combivert R6-S Instruction Manual

Power supply and regeneration unit
Hide thumbs Also See for combivert R6-S:
Table of Contents

Advertisement

Technical Data
3.2
Operating Environment Specifi cations
Defi nition According To
Operating Altitude
Specifi cations During Operation
Environment
Temperature
Humidity
Mechanical
Vibration
Contamination
Specifi cations During Transport
Environment
Temperature
Humidity
Mechanical
Vibration
Contamination
Specifi cations During Storage
Environment
Temperature
Humidity
Mechanical
Vibration
Contamination
Construction / protection
Environment Class
Defi nition According To
EMI disturbance creation (See instruction manual)
Conducted disturbance
Radiated disturbance
EMI Susceptibility
Burst - Control wires and bus com. EN 61000-4-4
Burst - Line supply EN 61000-4-4
Surge - Line supply EN 61000-4-5
Line supply fl uctuations; collapse
Line voltage symmetry / line
frequency variation
Installation altitude maximum 6,562 ft (2000 m). With installation altitudes over 3280 ft (1000 m) a de-rating of 1 %
per 328 ft must be taken into consideration.
Standard
EN 61800-2
EN 61800-5-1
60721-3-3
Railroad
Germ.Loyd
Shock
EN60721-3-3
Gas
Particle
60721-3-2
Railroad
Germ.Loyd
EN60721-3-3
Shock
EN60721-3-3
Gas
Particle
60721-3-2
Railroad
Germ.Loyd
EN60721-3-3
Shock
EN60721-3-3
Gas
Particle
EN60529
IEC 664-1
EN 61800-3
EN 55011
EN55011
ESD EN 61000-4-2
EMF EN6100-4-3
EN 61000-2-1
EN 61000-2-4
Classifi cation
Inverter Product Standard: Measurement specs.
Inverter Product Standard: General Safety
with 1% power derating per 100m above 1000m
3K3
(from 45°C to max. 55°C a power derating of 5%
3K3
EN50155
Max. oscillation amplitude 1 mm
max. accel. amplitude 7 m/s²
Part 7-3
3M1
max. 50m/s
3C2
3S2
2K3
2K3
EN50155
Max. oscillation amplitude 3.5 mm (2...9 Hz)
max. acceleration amplitude 15 m/s² (9...200 Hz),
Part 7-3
2M1
2M1
max. 100m/s
2C2
2S2
1K4
1K3
EN50155
Max. oscillation amplitude 1 mm (5...13 Hz)
max. acceleration amplitude 7 m/s² (13...200 Hz),
Part 7-3
1M1
1M1
max. 100m/s
1C2
1S2
IP20
C3
C3
8kV
AD (air charge) and CD (contact charge
2kV
4kV
1 / 2kV
Phase to phase / Phase to ground
10 V/m
Specifi cations
2000m above sea level
Range -10C ...45 °C
per 1°C can be applied.)
5...85% (no condensation)
(13...200 Hz)
; 30msec; half sinewave
2
Range -25 ...70 °C
(no condensation)
sinewave
; 11msec; half sinewave
2
Range -25 ...70 °C
(no condensation)
sinewave
; 11msec; half sinewave
2
Chassis
Pollution degree 2
Inverter Product Standard: EMI
Level A (Level B optional)
Level A
+10 %, -15 %; 90 %
3% / 2%
(5...13 Hz)
, sinewave
US - 13

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents