Technical Data; Standard Device Size - KEB Combivert R6-S Instruction Manual

Power supply and regenerative unit
Hide thumbs Also See for Combivert R6-S:
Table of Contents

Advertisement

3.

Technical Data

3.1

Standard device size

Device size
Housing size
Phases
Permitted mains forms
Rated voltage
Input voltage UL
Mains voltage range
Mains frequency
DC voltage range
Regeneration
Rated apparent output power
Rated active power
Max. power output
Max. active power
Rated regenerative current
Regenerative DC current
Overload current (E.OL) 60 s
Max. DC regenerative current 60 s
Power supply operation
Rated input power
Rated active power
Max. input power
Max. active power
Rated supply current
DC supply current
Overload current (E.OL) 60 s
Max. DC supply current 60 s
Overload disconnection (E.OL)
Overvoltage switch-off (E.OP)
Output rated voltage
Max. permissible DC link capacity
I
t Integral of the limiting load of the semiconduc-
2
tor
Max. permissible mains fuse type gR / aR
Mains fuse type RK5 rated current/min. voltage
Permissible aR fuse Siemens Sitor / Bussmann (no delta power
system)
Mains fuse type RK1 "fast acting" or "J fast acting" *)
Short-circuit factor at the connection point (S
Power dissipation at rated operation
Max. heat sink temperature
Bracket values obtain for operation at 230 V power supply.
*)
The overload current is specified for 1 minute. The overload cycle is 300 seconds. This corresponds to duty class 2
1)
EN 60146-1-1.
The current data are based on a fundamental frequency component of g=0.95. The fundamental frequency com-
2)
ponent or the effective value of the input current is dependent on load and line supply conditions. At uncontrolled
B6 converters the phase angle cosφ1 can be set to one, so the value of the fundamental frequency components is
equal to the value of the power factor.
If the DC infeed current > 85 A DC use two by two of the DC terminals (++ and --) to meet the requirements of the
3)
UL standard. The connection cables are parallel connected.
Please contact KEB for higher values.
4)
IT and delta power system after consultation KEB.
5)
*)
[V]
*)
[V]
[V]
[Hz]
[V
]
*)
DC
Sn *)
[kVA]
*)
[kW]
*)
[kVA]
*)
[kW]
[A]
[A
]
DC
1)
[A]
[A
]
DC
Sn *)
[kVA]
*)
[kW]
*)
[kVA]
[kW]
*)
[A]
2)
[A
]
DC
[A]
[A
]
DC
[%]
[V
]
DC
[V
]
DC
*)
[µF]
4)
[A
s]
2
[A]
*)
50 A / 480 V (50 A / 250 V)
3NC2240 / FWP-40A22FA 3NC2240 / FWP-40A22FA
50A / 480V (50A / 250V)
" / Sn) or (S
/ S
)
kn
scp
n
[W]
[°C]
Technical Data
15 (13)
E
3
TN, TT
5)
400 (230)
240/400/480
180...550 ±0 %
50 / 60 ±2
250...780 (UL: 340...680)
18
(10.5)
17
(10)
27
(15.5)
25.5
(15)
26
32
39
48
18
(10.5)
16
(10)
27
(15.5)
24
(14.5)
26
32
39
48
160
900
540 (310)
5000
(21500)
1200
40
90 A / 480V (90A / 250V)
90A / 480V (90A / 250V)
20 < S
" / S
< 350
kn
n
200
70
19 (16)
45
(26)
42
(23)
67.5
(39)
63
(34.5)
65
80
97.5
120
48.5
(28)
44.5
(25.5)
72.5
(42)
67
(38)
70
87
3)
105
130
160
5000
(21500)
4500
100
470
88
GB - 15