Technical Data
3.4

Operating conditions

Definition according to
Site altitude
Ambient conditions during operation
Climate
Mechanical
Contamination
Ambient conditions during transport
Climate
Mechanical
Contamination
Ambient conditions for the storage
Climate
Mechanical
Contamination
Type of protection
Environment
Overvoltage category
Definition according to
EMC emitted interference
Conducted interference emission
Radiated interferences
Interference immunity
Burst - control lines + bus EN 61000-4-4
Surge - mains supply EN 61000-4-5
Conducted immunity,
induced by high-frequency
GB - 18
EN 61800-2
EN 61800-5-1
Temperature
EN 60721-3-3
Humidity
Germ. Lloyd
Vibration
EN 60721-3-3
Temperature
Humidity
Vibration
EN 60721-3-2
Surge
Gas
Solids
Temperature
Humidity
EN 60721-3-1
Vibration
Surge
IEC 664-1
EN 618005-1
EN 61800-3
Static discharges EN 61000-4-2
Burst - mains supply EN 61000-4-4
EN 61000-4-6
fields
Standard/
Standard
class
3K3
3K3
Track
EN 50155
Part 7-3
3M4
Gas
3C2
Solids
3S2
2K3
2K3
2M1
2M1
2C2
2S2
1K4
1K3
1M2
1M2
Gas
1C2
Solids
1S2
EN 60529
IP20
Class III
C2
C2
8 kV
2 kV
4 kV
1 / 2 kV
10 V
Instructions
Inverter product standard:
Rated specifications
Inverter product standard:
General safety
max. 2000 m above sea level
(with site altitudes over 1000 m a derating of
1 % per 100 m must be taken into considera-
tion)
extended to -10...45 °C
(with temperature over 45°C to max. 55°C
a derating of 5 % per 1 K must be taken into
consideration)
5...85 % (without condensation)
max. amplitude of a vibration 1 mm
(5...13 Hz)
max. acceleration amplitude 7 m/s²
(13...200 Hz)
(without condensation)
max. vibration amplitude 3.5 mm (2...9 Hz)
max. acceleration amplitude 15 m/s² (9...200 Hz)
max. 100 m/s²; 11 ms
(without condensation)
max. vibration amplitude 1.5 mm (2...9 Hz)
max. acceleration amplitude 5 m/s² (9...200 Hz)
max. 40 m/s²; 22 ms
Pollution degree 2
Inverter product standard: EMC
with EMC filter and ferrite rings and motor
cable length < 100m
with EMC filter and ferrite rings
AD (air discharge) and CD (contact dis-
charge)
Phase-phase / phase-ground
0.15...80 MHz
continued on the next page