3.5 Connection of pneumatic air supply

Screw
socket
(Air intake)

3.6 Water filling (510, 530)

35201, ENG - rev. 3, 2006-03
The CR500 range must be connected to a pneumatic air network.
1. Connect the welder to the pneumatic air network via the screw
socket at the rear of the welder unit using a standard pneumatic air
connector.
2. (500 DA)Make sure that the set air pressure on the welder is 5 bar
(73 PSI). For setting the air pressure, refer to section 4.4 "Setting
the pneumatic air pressure".
(510, 530) Set the pressure regarding the setting on the display.
IMPORTANT! The air must be clean and free from oil and moisture. Use
filtration.
Use high-tech antifreeze. Mix 3 litre of water with 1 litre of high-tech anti-
freeze.
WARNING! Do not fill the water tank with anything but water (and
antifreeze agent, if needed). Improper handling may result in personal injury
and/or damage to the equipment.
IMPORTANT! Do not use water that is salt, brackish or rich in lime.If there
is any uncertainity regarding the quality of the water, pleaseuse destilled
water.
IMPORTANT! If the heater is used in temperatures below freezing point,
Car-O-Liner´s recommended antifreeze agent must be used.
1. Loosen the lid on the top of the water tank.
2. Fill the water tank with water mixed with antifreeze.
Car-O-Liner AB