Electrical Connection - Car-O-Liner CR35 Instruction Manual

Spotter movable dent fixer
Table of Contents

Advertisement

This machine complies with the 89/392/CEE directives and subsequent modifications and
supplements.

ELECTRICAL CONNECTION

The electrical connection of the spot welder to the mains must be made by qualified personnel.
The electrical connection must be made in compliance with the prescriptions of the EN 50063 CEI
26-6 and CEI 64/8 Standard - installation of resistance welders (spot welders) - to a grounded
power box provided with a differential circuit breaker having an adequate capacity for the power of
the spot welder (tab.1, p.6, Electrical Features) and complying with the CEI EN 60204/1
Standards.
Make sure that the size of the electrical line (conductor section) and the capacity of the fuses are
adequate.
Caution: The spot welders are SINGLE PHASE and provided with a power cord with two
leads, plus a third lead intended only for connection to the grounding system; therefore
they can be connected to a single phase power supply, or to a three phase power supply of
which only two of the three available phases will be used.