User Settings - Eaton BladeUPS User Manual

For use with eaton bladeups 5 kva to 60 kva (n+1) systems
Hide thumbs Also See for BladeUPS:
Table of Contents

Advertisement

Table 11. Menu Map for Display Functions
Main Menu
Submenu
UPS Status
Event Log
Measurements
Parallel System
Output
For more information
about measurements,
Battery
see "Metering" on
Input
page 118.
Load
Receptacle
Control
Go to Bypass
Mode
Start Battery
Test
Display Test
Settings

User Settings

Service
Settings
Identification
Turn UPS On/Off
On and Off
Options
User Settings
Table 12 displays the options that you can change.
Table 12. User Settings
Description
Set Date and Time
Display Contrast
Change Language
Relay Config
Signal Inputs
Eaton BladeUPS 5.1 kVA to 60 kVA (N+1) User's Guide 164201649—Rev 9 www.eaton.com/powerquality
Display Information or Menu Function
System Normal | High Efficiency Power: % /
Battery Resting | Battery Floating UPS in Parallel Mode /
Parallel Unit Number x / Units on CAN Bus / Units on Load
Displays up to 100 events and alarms
k
[by unit] / k
[Parallel total]
Voltage L-N and L-L / Current / Frequency / Power k
Voltage / Current / Runtime
Voltage L-N and L-L / Current / Frequency
Outlet Voltage / Outlet Current / Outlet Power k / Outlet Power kVA / Outlet Frequency
Transfers the UPS system to internal Bypass mode
hen this command is active, the option changes to Go to Normal Mode.
Schedules a battery test. The battery test may not start immediately.
Four different selectable tests for the front panel functions: the LEDs cycle through, the alarm
beep sounds, the backlight turns off and on, and the pixels scroll through to test the LCD.
Options for user-defined settings (see Table 14 for details).
Not available.
Type / Part Number / Serial Number / Firmware / Display / System Display / CAN Bridge
Turn UPS Off / Turn System On / Turn System Off
Available Settings
Set Year, Month, Day
Date: mm/dd/yyyy
Set Hours, Minutes
Time is a 24-hour clock.
Adjust contrast with up/down arrow buttons.
Select Language
Available languages depend on model and languages installed.
Relay: [Alarm-1] [X-Slot 1-1/2/3/4] or [X-Slot 2-1/2/3/4]
Setup: [On Battery] [Summary Alarm] [On Bypass] [UPS OK]
[custom] [empty]
Signal: [X-Slot-1] [X-Slot-2] [INPUT 1] [INPUT 2]
[signal inputs]
Logic: [0] [1]
For more information, see "Programmable Signal Inputs" on
page 111.
Operation
/ Power kVA / Power pf
Default Setting
01/01/2003
00:00
Moderate
English
Alarm 1: empty
X-Slots (1 or 2)
#1: UPS OK
#2: On Bypass
#3: Summary Alarm
#4: On Battery
<empty>
[1]
95