Mechanical specifications
The server conforms to the following mechanical specifications.
Mid Tower case size
Weight
Environmental specifications
The following specifications identify maximum environmental conditions. At
no time should the server run under conditions which violate these
specifications.
Temperature
Nonoperating
Operating
System heat output
Humidity
Nonoperating
Operating wet bulb
Shock
Operating
Packaged
Altitude
Operating
7.762 in. (19.715 cm) x 17.833 in. (45.296 cm) x 19.054 in.
(48.397 cm) (W x H x D).
38 lbs maximum (17.27 kg)
Maximum rate of change = 10° C per hour
-48.3° to 65.5° C (-55° to 150° F)
5° to 35° C (41° to 95° F); derated 0.5° C for every 1000 ft.
(305 m)
Btu/hr 850
95% relative (noncondensing) at 30° C (86° F)
Not to exceed 33° C (91.4° F) (with diskette drive or hard disk
drive)
2.0 g, 11 msec, 1/2 sine
Operational after 30-inch free fall (cosmetic damage may
occur)
10,000 ft. maximum
107
Specifications