and an event of this priority or higher occurs. SMS alarms may be configured using the
Configuration - Alarms > Event Settings > SMS web page
If no number is specified it is possible that the unit operates using the default message centre
for the GSM service to which you have subscribed.
SMS access level
The access level for SMS commands. The access level set here needs to match the level
required by the command sent by SMS for the command to be accepted.
Use x as a command separator (default is CR)
This parameter specifies the character to be used to separate multiple command lines when a
remote SMS sender is controlling the unit. The default separator is <CR> but some SMS
capable devices are not equipped with <CR> keys so an additional means of separating
multiple lines is required.
Allow CLI commands from the following SMS numbers.
You may specify up to 10 numbers. Specifying * permits commands from any SMS number.
Numbers are applied in the following input box. Click 'Add' to submit.
Related CLI commands - SIM Slot 1 (PPP 1)
Entity
modemcc
modemcc
modemcc
modemcc
modemcc
modemcc
Digi TransPort User Guide
Instance
Parameter
0
sms_interval
0
sms_replies
0
sms_concat
0
sca
0
sms_access
0
sms_cmd_sep
Values
Equivalent Web Parameter
Poll for incoming SMS
messages:-
Every n minutes
on/off
Enable command replies via SMS
Number
Concatenate replies
0 = off
10 = default
when enabled
Free text field
Use this SMS message centre
number n instead of the network
default
0 = Super
SMS access level:
(default)
1 = High
2 = Medium
3 = Low
4 = None
5 = HighLow
6 =
HighMedium
7 = CheckPar
Free text field
Use as a command separator