When connecting to an NTP time server in polled mode, it may be necessary to send polls at
intervals shorter than the minimum poll interval in order to speed up the synchronization
process. This parameter controls the interval between polls during the startup process. This
feature is useful in situations where the router only has an intermittent Internet connection.
Related CLI commands
Entity
Instance
ntp
n
ntp
n
ntp
n
ntp
n
ntp
n
ntp
n
ntp
n
ntp
n
ntp
n
ntp
n
Digi TransPort User Guide
Parameter
Values
driftppm
-10000 - +10000
precision
-10 - 0
inhibit_int
Blank,PPP,Ethernet
inhibit_add
0 - 255
server
Valid IP address or
hostname, such as
ntp1@timeserver.org
bcast
0,1
minpoll
3 - 14
maxpoll
3 – 14
burstint
0 – 255
server2
Valid IP address or
hostname, such as
ntp2@timeserver.org
Date and Time parameters
Equivalent Web Parameter
Initial Drift Compensation
Clock Precision Limit
Disable NTP when interface x,y
is out of service
x = Interface type
Disable NTP when interface
is out of service
y = interface number
NTP Server
Broadcast Mode
0 = disabled
1 = enabled
Poll Interval s1, s2
3 = 8
4 = 16
5 = 32
6 = 64
7 = 128
8 = 256
9 = 512
10 = 1024
11 = 2048
12 = 4096
13 = 8192
14 = 16384
Poll Interval s1,
s2
See 'minpoll' for values
Startup burst Interval
s
seconds
NTP Server
x,y